Deposit a Coin · setup 1 · seed 22
B601-RS · gpt-6-astra · SAM 3 + grasp model · 38 rounds · 47 min thinking · 6.6 s motion
“Pick up the coin from the holder and insert it precisely into the coin bank.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0vision_groundgeometry_query
Measure the coin and slot before selecting a grasp.
Next: Ground the coin and back-project visible coin and slot pixels.
Round 1grasp_plangeometry_query
Plan a left-arm grasp using T1, whose inspected preview isolates the exposed coin better than T0, which includes the holder.
Next: Generate grasp candidates and sample the bank slot’s surrounding surface.
Round 2grasp_execute · aborted
Candidate G0 is suitable for a guarded pickup attempt after reviewing both published previews.
Next: Execute G0’s approach, closure and lift probe.
Round 3move_pose · planner failed
Retreat upward before revising the grasp approach.
Next: Raise the left gripper 80 mm while preserving its orientation and open directive.
Round 4move_pose
Use a shorter upward retreat before revising the grasp orientation.
Next: Raise the left gripper 40 mm while preserving its orientation and gripper directive.
Round 5move_pose · planner failed
Reorient above the coin for a downward approach with jaws across its faces.
Next: Move above the coin at z=0.860 m with downward approach and approximately world-Y jaw alignment.
Round 6move_pose
Try the tilted standoff pose identified as reachable by the previous action’s IK search.
Next: Reorient above the coin with a 30-degree tilt from vertical.
Round 7set_gripper
Narrow the open jaws above the coin before descending.
Next: Apply one left-gripper close command at the current standoff.
Round 8set_gripper
Reopen the jaws before approaching the coin.
Next: Open the left gripper at the current standoff.
Round 9move_pose · not reached
The open left gripper is ready for a controlled approach to the coin’s upper rim; no grasp is established.
Next: Lower the left gripper toward the coin while holding its current orientation.
Round 10vision_segmentalign_plan
Replan the grasp orientation before further descent.
Next: Request coin masks and read-only alignment candidates.
Round 11grasp_plan
Replan the grasp using the current coin mask before further motion.
Next: Generate left-arm grasp candidates for inspected mask T0.
Round 12grasp_execute
Submit the only candidate with reported IK reachability to the execution clearance gate.
Next: Execute candidate grasp-1bb3441778ebb5ab85e6b93c.
Round 13grasp_plan
Check right-arm grasp options after the left candidate failed clearance.
Next: Generate right-arm grasp candidates from the current coin mask.
Round 14move_pose · planner failed
Try a new left-arm standoff with a horizontal jaw line before any contact approach.
Next: Move the open left gripper above and beside the coin with reduced vertical finger stagger.
Round 15move_pose · planner failed
Use an intermediate rotation to improve jaw alignment before descending.
Next: Rotate the left gripper halfway toward the estimated upper-edge grasp orientation, holding position.
Round 16move_pose
Try the smaller rotation admitted by the current IK diagnostic before approaching the coin.
Next: Rotate the left gripper through the reported reachable intermediate orientation while holding position.
Round 17move_pose · planner failed
Proceed with a short descent and reduce finger tilt before grasping.
Next: Move the left gripper to the next alignment pose, keeping it open.
Round 18move_pose
Use the controller-reported reachable intermediate pose to continue approaching the coin.
Next: Lower the open left gripper to the alternative pose reported by the IK search.
Round 19move_pose · planner failed
The open gripper remains above the coin; further approach is needed before closing.
Next: Lower the left gripper toward the coin’s upper rim while holding orientation.
Round 20move_pose
Use the reported reachable orientation to approach the coin’s upper rim.
Next: Move the left gripper to the alternative contact pose with reduced jaw tilt.
Round 21set_gripper · not reached
The observed upper rim overlaps the fingertip region enough to attempt closure.
Next: Close the left gripper around the coin’s upper rim.
Round 22move_pose · planner failed
Ready for a short lift test; grasp remains unverified.
Next: Raise the left gripper 40 mm while preserving its orientation and closed drive target.
Round 23move_pose
Grasp remains unverified; a smaller lift is appropriate.
Next: Request a 30 mm vertical lift while preserving orientation and the close directive.
Round 24set_gripper
The lift did not establish a secure grasp; reopen for a deeper grasp.
Next: Open the left gripper and inspect the resulting observation.
Round 25move_pose · planner failed
Reposition for a deeper pinch; no secure grasp is established.
Next: Lower the open left gripper to the revised grasp position.
Round 26move_pose
Try the shorter descent reported reachable by the current IK query.
Next: Move the open left gripper to the reachable intermediate contact pose.
Round 27set_gripper · not reached
The coin’s upper rim overlaps the fingers sufficiently for another pinch attempt; pickup remains unverified.
Next: Close the left gripper.
Round 28move_to · planner failed
Closure is consistent with contact; grasp remains unverified.
Next: Lift the left gripper 40 mm vertically while preserving orientation and closure.
Round 29move_to
Try the reported reachable 35 mm lift to test retention.
Next: Lift the left gripper 35 mm while preserving orientation and closure.
Round 30set_gripper
The coin was not retained; another grasp correction is needed.
Next: Open the left gripper before repositioning around the shifted coin.
Round 31vision_segment
The prior grasp was not retained. A new grasp must account for the coin now lying flat beside the holder.
Next: Segment the coin in the current left-wrist image.
Round 32grasp_plan
The coin is outside the holder and ungrasped. Plan a recovery grasp from its current position.
Next: Request a left-arm grasp plan for the inspected coin mask.
Round 33grasp_plan
No retained grasp or insertion is established. Check whether the right arm offers a feasible recovery grasp.
Next: Request a read-only right-arm grasp plan for the current coin target.
Round 34move_pose · planner failed
Pickup and insertion remain unsuccessful. Neither arm has an admitted grasp for the coin’s current flat pose.
Next: Raise the open left gripper 30 mm to clear the work area.
Round 35move_pose
No verified grasp or insertion. Use the reported reachable tilted pose to retreat.
Next: Raise the open left gripper using the alternative orientation reported by IK diagnostics.
Round 36wait_ticksobserve
Pickup and insertion remain unsuccessful; neither arm has an admitted grasp for the coin’s flat pose.
Next: Hold current commands for 10 ticks, then observe settling.
Round 37finish_episode
Task unsuccessful: the coin is on the table outside the bank; no retained grasp or insertion was achieved.
Next: End this attempt and record the unsuccessful outcome.
Milestones
| Milestone | Points |
|---|---|
| locate/approach coinR20 open jaws reached coin rim pose | 5 / 5 |
| grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R23 lift +9 mm then lost; R29 +8 mm then lost; never lifted clear | 0 / 25 |
| transport to bankno grasp | 0 / 15 |
| align coin with slotno | 0 / 15 |
| insert: coin inside bank, below slot planeno | 0 / 30 |
| release & retreat, coin stays depositedR30 open dropped coin flat beside holder (z -13 mm); end frame coin on table | 0 / 10 |
| Total | 5 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Upright thin coin never retained by rim pinch; 12 IK/planner failures; final open knocked coin onto table.