Deposit a Coin · setup 2 · seed 33
B601-RS · gpt-6.1-terra · SAM 3 + grasp model · 40 rounds · 18 min thinking · 10 s motion
“Pick up the coin from the holder and insert it precisely into the coin bank.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0geometry_queryvision_segment
The head view shows a small coin-like object in a holder near the piggy bank. Geometry and reachability must be measured before moving.
Next: Measure pixels on the coin and slot and request a coin segmentation.
Round 1reach_mapgrasp_plangeometry_query
The visible upright coin appears to be in the small holder near the center of the table. I will check a low grasp and the bank slot geometry.
Next: Run a left-arm reach map and grasp planning on the more narrowly segmented coin; measure points around the bank slot.
Round 2grasp_execute · completed
The first grasp proposal is a reasonable attempt: its preview places the jaws over the visible coin region, and its planned approach is IK-admitted.
Next: Execute the first current grasp candidate, then inspect its terminal result and fresh observations.
Round 3move_pose
The coin may be between the left fingers, but retention is not verified.
Next: Raise the left gripper 6 cm while holding its current orientation and closed directive.
Round 4geometry_querygeometry_queryvision_ground
The lift did not visibly remove the coin from its holder; a grasp is not established.
Next: Measure the coin in the left wrist image and the slot in the head image, and identify the coin for grasp planning.
Round 5reach_mapgrasp_planvision_ground
The coin remains in its holder; the last lift did not establish a grasp. The selected mask covers the visible coin but also includes some holder geometry.
Next: Check left-arm reach at the coin, generate grasp candidates, and locate the bank slot.
Round 6grasp_execute · completed
The coin appears to remain in the holder after the previous lift. A new grasp attempt is warranted.
Next: Execute the reviewed upper contact proposal for the left arm.
Round 7move_pose
The pickup is not verified; the coin appears to remain at the holder after the lift.
Next: Raise the left gripper to clear the holder, then inspect the resulting observation.
Round 8vision_segmentgeometry_query
The coin remains in the holder, so the pickup has not succeeded. A fresh grasp estimate should focus on the exposed coin rather than the holder.
Next: Segment the visible coin in the current left-wrist image and measure several points along its exposed edge.
Round 9reach_mapgrasp_plan
The coin appears to remain in its holder; the previous lift did not pick it up.
Next: Query low-height reachability and generate grasp candidates for the visible coin.
Round 10grasp_execute · aborted
The coin appears to remain in its holder; the previous lift did not establish a grasp. The current candidate preview places the jaws around the visible coin.
Next: Execute the highest-contact candidate and inspect its lift probe.
Round 11recover_pose
The grasp attempt failed before closure. Retreat to the previously reached pregrasp pose before replanning.
Next: Recover the left arm to its previous pose, then inspect the resulting observation.
Round 12geometry_queryvision_segmentreach_map
The coin still appears to be in its holder, and pickup has not been verified. A different approach needs to be assessed before another attempt.
Next: Measure and segment the coin in the current left-wrist view and check right-arm reachability at its previously estimated position.
Round 13grasp_planreach_map
The visible segmentation corresponds to the exposed coin. Plan a left-arm grasp before moving.
Next: Request a grasp plan and left-arm reach map for the current coin observation.
Round 14grasp_execute · completed
Candidate grasp-de6f4e18b441685f6737a2c4 is the best available attempt: its preview places the jaws across the exposed coin, and its proposed contact pose needs no support-height adjustment.
Next: Execute the current candidate through the grasp validation and action channel.
Round 15move_pose
The coin may be between the left jaws, but lift-off and retention are not yet verified.
Next: Raise the left gripper 4 cm while preserving its orientation and closed directive, then inspect the measured result and fresh views.
Round 16geometry_querygeometry_queryreach_map
The coin appears to have lifted clear of the holder, but stable retention is not yet established. The bank slot needs a more precise position estimate before transfer.
Next: Measure the coin and slot rim in the current RGB-D views, and check kinematic reach near the bank.
Round 17wait_ticks
The coin appears to have lifted clear of the holder, but stable retention still needs verification before transfer.
Next: Hold the current commands for five control ticks and inspect the resulting observation.
Round 18geometry_queryreach_mapreach_map
The coin appears to remain between the left jaws above the holder during the short hold, supporting a tentative pickup; transfer and insertion are not yet verified.
Next: Measure the visible coin edge and test the current gripper orientation near the bank at two heights.
Round 19reach_mapreach_map
The coin appears to have lifted from the holder and remained between the jaws during a short hold, but stable retention remains tentative. The current gripper orientation was not admitted at the sampled bank position.
Next: Test several candidate orientations at two heights above the slot using robot kinematics.
Round 20reach_map
The coin appears to have lifted clear and stayed between the left jaws during a short hold, but retention remains tentative. The current orientation was not admitted at the sampled bank position.
Next: Check a small intermediate grid before choosing a transfer or reorientation motion.
Round 21move_pose
The coin appears to remain between the left jaws after lift-off and a short hold, so an intermediate transfer is reasonable. Retention remains tentative.
Next: Move the left gripper to an intermediate point using an orientation admitted by the latest reach map, then inspect the action result and current images.
Round 22geometry_queryaction_query
The coin appears to have followed the left gripper during the transfer and remains between the fingers. Its alignment with the bank slot is not yet established.
Next: Measure the coin edge in the current wrist view and query the completed transfer action.
Round 23move_pose
The coin appears to have followed the left gripper from the holder and remained between the fingers. An approach above the bank is reasonable, but insertion alignment is not yet verified.
Next: Move the left gripper toward the slot while preserving the bank-reachable orientation and closed directive.
Round 24geometry_query
The coin is visibly between the left gripper fingers near the bank, but insertion and retention have not been verified.
Next: Measure the coin and slot in the current left-wrist RGB-D image.
Round 25geometry_query
The coin appears held above the bank, but its lower edge is offset from the slot. Further alignment is needed before lowering.
Next: Measure selected pixels in the current left-wrist image.
Round 26move_pose
The coin appears held above the bank; align it laterally with the slot before lowering.
Next: Shift the left gripper approximately 4 mm in negative X and 15 mm in negative Y, maintaining height and orientation.
Round 27geometry_query
The coin appears to remain at the left gripper beside the bank slot, but alignment and insertion are not established.
Next: Measure the coin and slot in the current left-wrist image.
Round 28move_pose
The coin appears held above the bank; a small lateral correction and partial descent are appropriate before release.
Next: Move the left gripper approximately 5 mm in negative X, 5 mm in negative Y, and 12 mm downward while preserving its orientation and closed directive.
Round 29geometry_query
The coin appears held above the bank, but the wrist image shows its lower edge offset from the slot. Precise alignment is not yet established.
Next: Measure points on the coin and slot in the current left wrist image.
Round 30geometry_queryaction_query
The coin appears to have followed the left gripper from the holder to the bank, but precise slot alignment and insertion remain unverified.
Next: Measure the visible coin edge and nearby slot rim in the current wrist view, and retrieve the last movement’s terminal result.
Round 31move_pose
The coin appears held above the slot, but insertion is not yet verified. A small alignment and downward adjustment is warranted.
Next: Move the left gripper about 2 mm toward the estimated slot center and 6 mm down while preserving its orientation and grip.
Round 32geometry_query
The coin appears to have followed the left gripper from the holder to the bank and is now at the slot. Insertion and release are not yet verified.
Next: Measure points on the coin edge and nearby slot rim in the current left-wrist view.
Round 33move_pose
The coin appears aligned with the slot, with its visible lower edge approximately 6 mm above the surrounding bank surface. Insertion remains unverified.
Next: Lower the left gripper 6 mm while preserving its orientation and closed directive.
Round 34set_gripper · not reached
The coin appears aligned with and partly inside the bank slot. Release is the next step; insertion is not yet verified.
Next: Open the left gripper, then inspect the measured result and the coin.
Round 35move_pose · planner failed
The coin appears to be at the bank slot, and the jaws have opened substantially. Release and insertion remain unverified.
Next: Raise the left gripper while preserving its orientation and current opening, then inspect the resulting observation and action result.
Round 36move_pose
The coin appears to be at the bank slot, but insertion and stability after retreat are not verified.
Next: Raise the left gripper by 0.025 m while holding its orientation.
Round 37wait_ticksaction_query
The coin appears to remain upright at the bank slot after the gripper retreated, but its insertion depth and stability are not yet verified.
Next: Hold the current commands for 20 control ticks, then inspect the resulting observation; retrieve the retreat action’s terminal record.
Round 38move_pose · planner failed
The coin appears upright at the bank slot, but insertion and stability after retreat remain unverified.
Next: Raise the left gripper while preserving its current orientation and opening.
Round 39move_posewait_ticksobserve
The coin appears upright at the bank slot, but insertion and stable placement are unverified.
Next: Retreat the left gripper using the nearby IK-admitted orientation, then allow settling and observe.
Milestones
| Milestone | Points |
|---|---|
| locate/approach coinR14 grasp_execute | 5 / 5 |
| grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R14 +28 mm, R15 +66 mm, R17 hold, R21 +120 mm with gripper | 25 / 25 |
| transport to bankR21/R23 coin carried 218 mm to bank at +119 mm | 15 / 15 |
| align coin with slotR26-R33 small deltas bring coin upright into slot (left_wrist f341) | 15 / 15 |
| insert: coin inside bank, below slot planefinal coin z 0.885: upright, only lower edge in slot (left_wrist f424), not inside | 0 / 30 |
| release & retreat, coin stays depositedR34 open, R36/R39 retreat; coin stays wedged upright, not deposited | 5 / 10 |
| Total | 65 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Coin seated only at the slot mouth and released; no push-through below slot plane.