Deposit a Coin · setup 5 · seed 33

B601-RS · gpt-6-astra · full object info · 35 rounds · 30 min thinking · 11.8 s motion

Goal not reachedProgress 5RoboDojo reward 0

“Pick up the coin from the holder and insert it precisely into the coin bank.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0scene_truthgeometry_query

    Inspect geometry before planning a grasp.

    Next: Request scene truth and RGB-D measurements.

  2. Round 1reach_mapscene_truth

    The coin is upright in its holder; a downward grasp across its thin faces is appropriate if reachable.

    Next: Check the left arm at the coin with the proposed jaw orientation and retry bank geometry.

  3. Round 2move_pose

    A tilted pinch of the exposed coin is feasible; approach above it first.

    Next: Move the left gripper to the pregrasp pose.

  4. Round 3set_gripperset_gripperset_gripper

    Narrow the gripper above the coin before descending.

    Next: Apply three preparatory close commands at the current safe height.

  5. Round 4reach_mapscene_truthset_gripper

    Reopen the jaws before descending; no grasp has occurred.

    Next: Check reachability, query coin truth, and open the left gripper.

  6. Round 5move_pose

    Proceed with the reach-map-admitted descent; inspect the measured pose before closing.

    Next: Lower the open left gripper to the exposed coin rim.

  7. Round 6set_gripper

    The exposed upper coin overlaps the distal grasp region; attempt a face pinch.

    Next: Close the left gripper at its current pose.

  8. Round 7move_toscene_truth

    Closure is consistent with coin contact; a test lift is needed.

    Next: Lift the left gripper 45 mm, holding orientation and closure, then query coin pose.

  9. Round 8set_gripperreach_map

    The first grasp failed; adjust jaw alignment and contact depth.

    Next: Reopen the left gripper and check candidate orientations before descending.

  10. Round 9move_pose

    Use the admitted orientation to improve face alignment and contact depth.

    Next: Lower the open left gripper with its jaw axis aligned to the coin normal.

  11. Round 10set_gripper · not reached

    Proceed with the second upper-rim pinch.

    Next: Close the left gripper on the coin.

  12. Round 11move_toscene_truth

    Coin contact is plausible; grasp remains unverified.

    Next: Lift the left gripper 45 mm while preserving orientation and closure, then query coin pose.

  13. Round 12set_gripperscene_truthreach_map

    Second grasp failed; adjust contact depth before retrying.

    Next: Reopen left gripper, query coin truth, and test the lower target.

  14. Round 13move_pose

    Attempt a deeper face pinch using the reach-map-admitted orientation.

    Next: Lower the open left gripper to nominal fingertip height 0.777 m.

  15. Round 14set_gripper · not reached

    Proceed with the deeper face pinch; retention remains unverified.

    Next: Close the left gripper around the exposed coin.

  16. Round 15move_toscene_truth

    Contact is plausible; grasp remains unverified.

    Next: Lift the left gripper 45 mm, then query coin pose.

  17. Round 16set_gripperreach_map

    Third pinch failed; test an oblique grasp after checking reachability.

    Next: Open the left gripper and query oblique orientations at the coin.

  18. Round 17move_pose

    Attempt a revised oblique pinch after three failed retention tests.

    Next: Descend open using the reach-map-admitted orientation, then inspect before closing.

  19. Round 18move_pose

    Correct lateral coin-to-pad alignment before closing.

    Next: Shift the open left gripper 14 mm along its local Z axis.

  20. Round 19set_gripper · not reached

    The corrected pose provides better overlap for a fourth pinch attempt.

    Next: Close the left gripper on the exposed coin.

  21. Round 20move_toscene_truth

    Contact is plausible; retention remains unverified.

    Next: Lift the left gripper 45 mm while preserving orientation and closure, then inspect coin truth and fresh images.

  22. Round 21reach_mapset_gripper

    Fourth grasp failed; prepare a corrected face pinch.

    Next: Test the revised orientation and reopen the elevated left gripper.

  23. Round 22move_pose

    Proceed with the reach-tested, centered face-pinch approach; inspect alignment before closing.

    Next: Lower the open left gripper using the revised orientation and precision intent.

  24. Round 23move_pose

    Refine lateral alignment before closing on the coin.

    Next: Shift the open left gripper 11 mm along its local Z axis.

  25. Round 24move_pose

    The coin’s middle remains outside the estimated finger-pad span; correct lateral alignment before closing.

    Next: Shift the open left gripper 11 mm along its local Z axis, preserving orientation.

  26. Round 25set_gripper · not reached

    The coin face now overlaps the finger pads sufficiently to attempt closure.

    Next: Close the left gripper on the exposed coin face.

  27. Round 26move_toscene_truth

    Contact is plausible; grasp remains unverified. Perform a lift check.

    Next: Lift left gripper 45 mm while preserving orientation and closure, then query coin pose.

  28. Round 27set_gripperreach_map

    Fifth grasp failed. Assess an edge grip across the coin diameter.

    Next: Reopen above the holder and test edge-grip orientations.

  29. Round 28move_pose · planner failed

    Try the reach-admitted edge-grip approach after five failed face pinches.

    Next: Approach open with the jaw line across the coin diameter.

  30. Round 29reach_mapreach_map

    The coin remains in its holder; check an approach route before another attempt.

    Next: Test the edge-grip orientation and the planner-suggested alternative at both heights.

  31. Round 30move_pose

    Try the alternative edge-grip orientation admitted at both approach and contact heights.

    Next: Approach the coin with open jaws using the tested alternative orientation.

  32. Round 31move_pose

    Correct lateral alignment before attempting the edge grip.

    Next: Shift the open left gripper toward the coin plane while holding orientation.

  33. Round 32set_gripper

    The revised edge grip is aligned for a closure attempt.

    Next: Close the left gripper on the coin’s opposing edges.

  34. Round 33move_to

    Grasp remains unverified; insertion is incomplete.

    Next: Request a 30 mm vertical lift while maintaining closure.

  35. Round 34finish_episode

    Pickup failed; the coin was not inserted.

    Next: End the run and record the unsuccessful outcome.

Milestones

MilestonePoints
locate/approach coinR5 jaws at coin5 / 5
grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R11 coin +6 mm then lost; six pinch cycles, none retained0 / 25
transport to bankno0 / 15
align coin with slotno0 / 15
insert: coin inside bank, below slot planeno0 / 30
release & retreat, coin stays depositedno0 / 10
Total5 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Rim pinch on upright coin never retained despite exact pose from scene_truth.