Deposit a Coin · setup 5 · seed 33
B601-RS · gpt-6-astra · full object info · 35 rounds · 30 min thinking · 11.8 s motion
“Pick up the coin from the holder and insert it precisely into the coin bank.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0scene_truthgeometry_query
Inspect geometry before planning a grasp.
Next: Request scene truth and RGB-D measurements.
Round 1reach_mapscene_truth
The coin is upright in its holder; a downward grasp across its thin faces is appropriate if reachable.
Next: Check the left arm at the coin with the proposed jaw orientation and retry bank geometry.
Round 2move_pose
A tilted pinch of the exposed coin is feasible; approach above it first.
Next: Move the left gripper to the pregrasp pose.
Round 3set_gripperset_gripperset_gripper
Narrow the gripper above the coin before descending.
Next: Apply three preparatory close commands at the current safe height.
Round 4reach_mapscene_truthset_gripper
Reopen the jaws before descending; no grasp has occurred.
Next: Check reachability, query coin truth, and open the left gripper.
Round 5move_pose
Proceed with the reach-map-admitted descent; inspect the measured pose before closing.
Next: Lower the open left gripper to the exposed coin rim.
Round 6set_gripper
The exposed upper coin overlaps the distal grasp region; attempt a face pinch.
Next: Close the left gripper at its current pose.
Round 7move_toscene_truth
Closure is consistent with coin contact; a test lift is needed.
Next: Lift the left gripper 45 mm, holding orientation and closure, then query coin pose.
Round 8set_gripperreach_map
The first grasp failed; adjust jaw alignment and contact depth.
Next: Reopen the left gripper and check candidate orientations before descending.
Round 9move_pose
Use the admitted orientation to improve face alignment and contact depth.
Next: Lower the open left gripper with its jaw axis aligned to the coin normal.
Round 10set_gripper · not reached
Proceed with the second upper-rim pinch.
Next: Close the left gripper on the coin.
Round 11move_toscene_truth
Coin contact is plausible; grasp remains unverified.
Next: Lift the left gripper 45 mm while preserving orientation and closure, then query coin pose.
Round 12set_gripperscene_truthreach_map
Second grasp failed; adjust contact depth before retrying.
Next: Reopen left gripper, query coin truth, and test the lower target.
Round 13move_pose
Attempt a deeper face pinch using the reach-map-admitted orientation.
Next: Lower the open left gripper to nominal fingertip height 0.777 m.
Round 14set_gripper · not reached
Proceed with the deeper face pinch; retention remains unverified.
Next: Close the left gripper around the exposed coin.
Round 15move_toscene_truth
Contact is plausible; grasp remains unverified.
Next: Lift the left gripper 45 mm, then query coin pose.
Round 16set_gripperreach_map
Third pinch failed; test an oblique grasp after checking reachability.
Next: Open the left gripper and query oblique orientations at the coin.
Round 17move_pose
Attempt a revised oblique pinch after three failed retention tests.
Next: Descend open using the reach-map-admitted orientation, then inspect before closing.
Round 18move_pose
Correct lateral coin-to-pad alignment before closing.
Next: Shift the open left gripper 14 mm along its local Z axis.
Round 19set_gripper · not reached
The corrected pose provides better overlap for a fourth pinch attempt.
Next: Close the left gripper on the exposed coin.
Round 20move_toscene_truth
Contact is plausible; retention remains unverified.
Next: Lift the left gripper 45 mm while preserving orientation and closure, then inspect coin truth and fresh images.
Round 21reach_mapset_gripper
Fourth grasp failed; prepare a corrected face pinch.
Next: Test the revised orientation and reopen the elevated left gripper.
Round 22move_pose
Proceed with the reach-tested, centered face-pinch approach; inspect alignment before closing.
Next: Lower the open left gripper using the revised orientation and precision intent.
Round 23move_pose
Refine lateral alignment before closing on the coin.
Next: Shift the open left gripper 11 mm along its local Z axis.
Round 24move_pose
The coin’s middle remains outside the estimated finger-pad span; correct lateral alignment before closing.
Next: Shift the open left gripper 11 mm along its local Z axis, preserving orientation.
Round 25set_gripper · not reached
The coin face now overlaps the finger pads sufficiently to attempt closure.
Next: Close the left gripper on the exposed coin face.
Round 26move_toscene_truth
Contact is plausible; grasp remains unverified. Perform a lift check.
Next: Lift left gripper 45 mm while preserving orientation and closure, then query coin pose.
Round 27set_gripperreach_map
Fifth grasp failed. Assess an edge grip across the coin diameter.
Next: Reopen above the holder and test edge-grip orientations.
Round 28move_pose · planner failed
Try the reach-admitted edge-grip approach after five failed face pinches.
Next: Approach open with the jaw line across the coin diameter.
Round 29reach_mapreach_map
The coin remains in its holder; check an approach route before another attempt.
Next: Test the edge-grip orientation and the planner-suggested alternative at both heights.
Round 30move_pose
Try the alternative edge-grip orientation admitted at both approach and contact heights.
Next: Approach the coin with open jaws using the tested alternative orientation.
Round 31move_pose
Correct lateral alignment before attempting the edge grip.
Next: Shift the open left gripper toward the coin plane while holding orientation.
Round 32set_gripper
The revised edge grip is aligned for a closure attempt.
Next: Close the left gripper on the coin’s opposing edges.
Round 33move_to
Grasp remains unverified; insertion is incomplete.
Next: Request a 30 mm vertical lift while maintaining closure.
Round 34finish_episode
Pickup failed; the coin was not inserted.
Next: End the run and record the unsuccessful outcome.
Milestones
| Milestone | Points |
|---|---|
| locate/approach coinR5 jaws at coin | 5 / 5 |
| grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R11 coin +6 mm then lost; six pinch cycles, none retained | 0 / 25 |
| transport to bankno | 0 / 15 |
| align coin with slotno | 0 / 15 |
| insert: coin inside bank, below slot planeno | 0 / 30 |
| release & retreat, coin stays depositedno | 0 / 10 |
| Total | 5 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Rim pinch on upright coin never retained despite exact pose from scene_truth.