Deposit a Coin · setup 6 · seed 33
ARX X5 · gpt-6-astra · full object info · 35 rounds · 26 min thinking · 5.2 s motion
“Pick up the coin from the holder and insert it precisely into the coin bank.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0scene_truthgeometry_query
Inspect geometry before choosing the coin grasp.
Next: Query scene geometry and measure the visible coin/holder region.
Round 1reach_mapgeometry_query
A top-down pinch across the coin faces is appropriate, subject to reachability.
Next: Check the left arm's grasp orientation and measure the slot.
Round 2move_pose
The left arm can reach the planned top-down coin pinch.
Next: Move the open left gripper above the coin with its jaws aligned to the coin faces.
Round 3move_pose
The gripper is aligned for a top-down pinch of the exposed coin faces.
Next: Lower the open left gripper to the recorded grasp height.
Round 4set_gripper · not reached
The exposed coin is aligned for incremental closure.
Next: Apply the first limited left-gripper close.
Round 5move_posescene_truth
Contact is consistent with a coin pinch; grasp retention remains unverified.
Next: Lift the left gripper vertically 50 mm, preserving orientation and closure; inspect live object poses.
Round 6set_gripperreach_map
The first grasp failed; retry with deeper pad contact.
Next: Open the left gripper and check reach at a 0.777 m fingertip height.
Round 7move_pose
Proceed with the deeper, top-down approach admitted by reach_map.
Next: Lower left link6 to [-0.1266,-0.1741,0.9346] m with jaws open.
Round 8set_gripper · not reached
Ready for the second coin pinch at the deeper recorded contact height.
Next: Close the left gripper and inspect terminal feedback.
Round 9move_toscene_truth
Closure is consistent with contact; grasp remains unverified.
Next: Lift the left gripper vertically 50 mm while preserving orientation and closure.
Round 10set_gripperscene_truth
The second grasp failed to retain the coin.
Next: Open the raised left gripper, then remeasure the coin.
Round 11reach_map
Previous grasps slipped; check reach for a slightly deeper pinch and use a smaller lift test.
Next: Check the proposed downward grasp orientation before approaching.
Round 12move_pose
Proceed with the recorded deeper coin pinch approach; reach_map admitted this pose.
Next: Lower the open left gripper to the planned contact height.
Round 13set_gripper · not reached
Ready to attempt the deeper face pinch.
Next: Close the left gripper on the coin.
Round 14move_posescene_truth
Contact is plausible; grasp retention remains unverified.
Next: Lift the left gripper 15 mm with its current orientation and retained grip drive, then inspect live object poses.
Round 15set_gripperreach_mapscene_truth
The third face pinch failed to retain the coin. Prepare a pinch across its diameter.
Next: Open the left gripper and check reach for a downward edge pinch.
Round 16move_pose
Change to a pinch across the coin’s diameter after three failed face pinches.
Next: Rotate open jaws and lower to the admitted edge-pinch pose.
Round 17set_gripper · not reached
Ready to test the edge pinch; grasp remains unverified.
Next: Close the left gripper across the coin diameter.
Round 18move_posescene_truth
Test retention with a small vertical lift.
Next: Lift the left gripper 20 mm, preserving orientation and grip, then query live object poses.
Round 19move_posescene_truth
The coin did not follow the lift reliably; retention remains unverified.
Next: Lower the left gripper 16.7 mm while preserving its orientation and closing drive.
Round 20set_gripper · not reached
Coin pickup remains unverified; settle the rim pinch before a smaller lift test.
Next: Refresh the left close command at the current contact pose.
Round 21move_posescene_truth
Closure is consistent with rim contact; grasp remains unverified.
Next: Lift the left gripper 8 mm while preserving orientation and closing drive, then inspect live object poses.
Round 22move_posescene_truth
Coin retention remains unverified; test another small lift.
Next: Lift the left gripper 5 mm while preserving orientation and grip.
Round 23move_posescene_truth
Coin following improved; another short lift is needed to verify holder clearance.
Next: Lift 10 mm with the current grip, then inspect coin pose.
Round 24move_posescene_truthreach_map
The coin now follows the gripper; proceed with a clearance lift.
Next: Raise the coin 60 mm and check bank approach reachability.
Round 25move_posescene_truth
Coin retention is supported by matching motion; raise further before transport.
Next: Raise vertically to clear the bank, preserving the grip.
Round 26move_pose · planner failedscene_truth
Coin retention is supported by matching motion across successive lifts; proceed above the bank.
Next: Translate above the bank and align approximately with the slot, preserving the grip.
Round 27reach_map
Check a lower, corrected alignment pose before transport.
Next: Query reachability at fingertip height 0.915 m.
Round 28move_posescene_truth
Use the corrected pose admitted by the round-27 reach map.
Next: Move above the slot while preserving the grip, then query scene geometry.
Round 29reach_map
Coin retention persisted during transport; refine alignment before insertion.
Next: Check reach for the corrected orientation and final fingertip height.
Round 30move_posescene_truth
The corrected insertion orientation is reachable; proceed to the alignment waypoint.
Next: Lower the retained coin to approximately 0.900 m center height and inspect live geometry.
Round 31move_posescene_truth
Coin remains retained and aligned for insertion.
Next: Lower the coin into the slot while preserving the grip.
Round 32set_gripperscene_truth
Coin appears aligned and partially inserted; ready to release.
Next: Open the left gripper, then inspect the coin’s live pose.
Round 33move_posewait_ticksscene_truth
The coin appears to have passed through the slot; post-retreat stability remains unverified.
Next: Raise the open gripper 30 mm, wait 20 ticks, and inspect the coin pose.
Round 34finish_episode
Coin insertion is supported by the release trajectory and stable post-retreat position.
Next: Finish the episode.
Milestones
| Milestone | Points |
|---|---|
| locate/approach coinR3 jaws at coin | 5 / 5 |
| grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R23 +18, R24 +69, R25 +150 mm following | 25 / 25 |
| transport to bankR28 coin carried 198 mm to bank (+135 mm) | 15 / 15 |
| align coin with slotR30-R31 lowered edge-on into slot (left_wrist f190 coin in slot) | 15 / 15 |
| insert: coin inside bank, below slot planeR32 open: coin fell 107 mm to z 0.779 at bank xy (-0.327,-0.180) = inside bank (between bottom 0.773 and center 0.82); left_wrist f197/f221 slot empty, no coin outside | 30 / 30 |
| release & retreat, coin stays depositedR33 retreat +30 mm, 20-tick wait, coin stable | 10 / 10 |
| Total | 100 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.