Deposit a Coin · setup 6 · seed 33

ARX X5 · gpt-6-astra · full object info · 35 rounds · 26 min thinking · 5.2 s motion

Goal reachedProgress 100RoboDojo reward 0

“Pick up the coin from the holder and insert it precisely into the coin bank.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0scene_truthgeometry_query

    Inspect geometry before choosing the coin grasp.

    Next: Query scene geometry and measure the visible coin/holder region.

  2. Round 1reach_mapgeometry_query

    A top-down pinch across the coin faces is appropriate, subject to reachability.

    Next: Check the left arm's grasp orientation and measure the slot.

  3. Round 2move_pose

    The left arm can reach the planned top-down coin pinch.

    Next: Move the open left gripper above the coin with its jaws aligned to the coin faces.

  4. Round 3move_pose

    The gripper is aligned for a top-down pinch of the exposed coin faces.

    Next: Lower the open left gripper to the recorded grasp height.

  5. Round 4set_gripper · not reached

    The exposed coin is aligned for incremental closure.

    Next: Apply the first limited left-gripper close.

  6. Round 5move_posescene_truth

    Contact is consistent with a coin pinch; grasp retention remains unverified.

    Next: Lift the left gripper vertically 50 mm, preserving orientation and closure; inspect live object poses.

  7. Round 6set_gripperreach_map

    The first grasp failed; retry with deeper pad contact.

    Next: Open the left gripper and check reach at a 0.777 m fingertip height.

  8. Round 7move_pose

    Proceed with the deeper, top-down approach admitted by reach_map.

    Next: Lower left link6 to [-0.1266,-0.1741,0.9346] m with jaws open.

  9. Round 8set_gripper · not reached

    Ready for the second coin pinch at the deeper recorded contact height.

    Next: Close the left gripper and inspect terminal feedback.

  10. Round 9move_toscene_truth

    Closure is consistent with contact; grasp remains unverified.

    Next: Lift the left gripper vertically 50 mm while preserving orientation and closure.

  11. Round 10set_gripperscene_truth

    The second grasp failed to retain the coin.

    Next: Open the raised left gripper, then remeasure the coin.

  12. Round 11reach_map

    Previous grasps slipped; check reach for a slightly deeper pinch and use a smaller lift test.

    Next: Check the proposed downward grasp orientation before approaching.

  13. Round 12move_pose

    Proceed with the recorded deeper coin pinch approach; reach_map admitted this pose.

    Next: Lower the open left gripper to the planned contact height.

  14. Round 13set_gripper · not reached

    Ready to attempt the deeper face pinch.

    Next: Close the left gripper on the coin.

  15. Round 14move_posescene_truth

    Contact is plausible; grasp retention remains unverified.

    Next: Lift the left gripper 15 mm with its current orientation and retained grip drive, then inspect live object poses.

  16. Round 15set_gripperreach_mapscene_truth

    The third face pinch failed to retain the coin. Prepare a pinch across its diameter.

    Next: Open the left gripper and check reach for a downward edge pinch.

  17. Round 16move_pose

    Change to a pinch across the coin’s diameter after three failed face pinches.

    Next: Rotate open jaws and lower to the admitted edge-pinch pose.

  18. Round 17set_gripper · not reached

    Ready to test the edge pinch; grasp remains unverified.

    Next: Close the left gripper across the coin diameter.

  19. Round 18move_posescene_truth

    Test retention with a small vertical lift.

    Next: Lift the left gripper 20 mm, preserving orientation and grip, then query live object poses.

  20. Round 19move_posescene_truth

    The coin did not follow the lift reliably; retention remains unverified.

    Next: Lower the left gripper 16.7 mm while preserving its orientation and closing drive.

  21. Round 20set_gripper · not reached

    Coin pickup remains unverified; settle the rim pinch before a smaller lift test.

    Next: Refresh the left close command at the current contact pose.

  22. Round 21move_posescene_truth

    Closure is consistent with rim contact; grasp remains unverified.

    Next: Lift the left gripper 8 mm while preserving orientation and closing drive, then inspect live object poses.

  23. Round 22move_posescene_truth

    Coin retention remains unverified; test another small lift.

    Next: Lift the left gripper 5 mm while preserving orientation and grip.

  24. Round 23move_posescene_truth

    Coin following improved; another short lift is needed to verify holder clearance.

    Next: Lift 10 mm with the current grip, then inspect coin pose.

  25. Round 24move_posescene_truthreach_map

    The coin now follows the gripper; proceed with a clearance lift.

    Next: Raise the coin 60 mm and check bank approach reachability.

  26. Round 25move_posescene_truth

    Coin retention is supported by matching motion; raise further before transport.

    Next: Raise vertically to clear the bank, preserving the grip.

  27. Round 26move_pose · planner failedscene_truth

    Coin retention is supported by matching motion across successive lifts; proceed above the bank.

    Next: Translate above the bank and align approximately with the slot, preserving the grip.

  28. Round 27reach_map

    Check a lower, corrected alignment pose before transport.

    Next: Query reachability at fingertip height 0.915 m.

  29. Round 28move_posescene_truth

    Use the corrected pose admitted by the round-27 reach map.

    Next: Move above the slot while preserving the grip, then query scene geometry.

  30. Round 29reach_map

    Coin retention persisted during transport; refine alignment before insertion.

    Next: Check reach for the corrected orientation and final fingertip height.

  31. Round 30move_posescene_truth

    The corrected insertion orientation is reachable; proceed to the alignment waypoint.

    Next: Lower the retained coin to approximately 0.900 m center height and inspect live geometry.

  32. Round 31move_posescene_truth

    Coin remains retained and aligned for insertion.

    Next: Lower the coin into the slot while preserving the grip.

  33. Round 32set_gripperscene_truth

    Coin appears aligned and partially inserted; ready to release.

    Next: Open the left gripper, then inspect the coin’s live pose.

  34. Round 33move_posewait_ticksscene_truth

    The coin appears to have passed through the slot; post-retreat stability remains unverified.

    Next: Raise the open gripper 30 mm, wait 20 ticks, and inspect the coin pose.

  35. Round 34finish_episode

    Coin insertion is supported by the release trajectory and stable post-retreat position.

    Next: Finish the episode.

Milestones

MilestonePoints
locate/approach coinR3 jaws at coin5 / 5
grasp: lifted off holder and follows gripper (>=1 s sim or >=100 mm travel)R23 +18, R24 +69, R25 +150 mm following25 / 25
transport to bankR28 coin carried 198 mm to bank (+135 mm)15 / 15
align coin with slotR30-R31 lowered edge-on into slot (left_wrist f190 coin in slot)15 / 15
insert: coin inside bank, below slot planeR32 open: coin fell 107 mm to z 0.779 at bank xy (-0.327,-0.180) = inside bank (between bottom 0.773 and center 0.82); left_wrist f197/f221 slot empty, no coin outside30 / 30
release & retreat, coin stays depositedR33 retreat +30 mm, 20-tick wait, coin stable10 / 10
Total100 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. None (goal achieved; robot not returned home, which the source reward also requires).