Insert the Tubes · setup 1 · seed 47

B601-RS · gpt-6-astra · SAM 3 + grasp model · 40 rounds · 37 min thinking · 11.9 s motion

Goal not reachedProgress 51RoboDojo reward 0

“Insert the three tubes into the rack one by one.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_segmentgeometry_query

    Locate all three tubes and estimate rack geometry before planning the first grasp.

    Next: Segment the three visible tubes and measure rack surface points.

  2. Round 1grasp_plan

    The leftmost tube is a suitable first target for the left arm.

    Next: Generate grasp proposals for the leftmost tube.

  3. Round 2grasp_execute · completed

    Attempt the leftmost tube using the highest-clearance reviewed candidate.

    Next: Execute candidate grasp-b6c4c23721d39fb84d5d544c with the left arm.

  4. Round 3action_querymove_pose · planner failedwait_ticks

    The first tube appears lifted; verify retention with a further vertical lift before transport.

    Next: Query the grasp result, raise the left gripper 10 cm while preserving closure, then settle briefly.

  5. Round 4move_posewait_ticks

    The first tube appears retained above the table; verify following with a smaller lift before reorienting it.

    Next: Lift the left gripper 5 cm while preserving orientation and closure.

  6. Round 5move_pose · planner failed

    The first tube appears retained after lift and settling; rotate it tip-down before rack alignment.

    Next: Rotate the left gripper at its current position using the measured tube axis.

  7. Round 6move_pose · planner failed

    Raise and partially rotate the first tube before attempting rack alignment.

    Next: Move the left gripper upward and inward with approximately 67° rotation, preserving closure.

  8. Round 7move_pose

    Use the controller’s reachable alternative to raise and partially rotate the first tube.

    Next: Move the left arm to the reported alternative pose while preserving its gripper directive.

  9. Round 8move_pose · planner failed

    Raise and orient the first tube upright before assessing a transfer to the right gripper.

    Next: Move the left gripper to the numerically reachable elevated upright pose, maintaining closure.

  10. Round 9move_pose · not reached

    Try the smaller intermediate pose admitted by the controller’s sampled IK check. No tubes are verified placed.

    Next: Raise and partially rotate the left gripper to the sampled reachable intermediate pose, preserving closure.

  11. Round 10recover_pose

    Recover the left arm to its previous raised configuration while preserving the gripper command.

    Next: Request left-arm recovery to the previous measured joint configuration.

  12. Round 11vision_segment

    The first tube was lost during recovery; no insertion is verified. Select the unobstructed rightmost tube for a new grasp.

    Next: Segment the rightmost tube in the current head image.

  13. Round 12action_querygrasp_plan

    Plan a right-arm pickup of the unobstructed rightmost tube. No tubes are verified placed.

    Next: Query the recovery result and generate right-arm grasp proposals for the inspected target.

  14. Round 13grasp_execute · completed

    Attempt the rightmost tube with the reviewed right-arm candidate G0.

    Next: Execute grasp-f631c0753562a1eeec93258a; inspect its terminal action result and subsequent images.

  15. Round 14action_querymove_posewait_ticks

    The right-hand tube appears lifted; retention still needs verification. No tubes are placed.

    Next: Lift the right gripper 5 cm, preserve its grip, then settle for five ticks.

  16. Round 15move_pose · planner failed

    Right-tube retention is supported; no tubes are verified placed.

    Next: Raise and rotate the right-hand tube upright while preserving closure.

  17. Round 16action_querymove_pose

    Use the shorter pose sampled as reachable by the controller; no tube insertion is verified.

    Next: Query the failed action, then raise and partially rotate the right gripper while preserving its grip.

  18. Round 17action_querymove_to · planner failed

    Tube retention and following are supported; no tubes have been placed.

    Next: Raise the right gripper approximately 10 cm while preserving orientation and grip.

  19. Round 18action_querymove_to

    Use a shorter lift within the controller’s sampled reachable range.

    Next: Query the failed action, then lift the right gripper to z=1.02 m while preserving orientation and closure.

  20. Round 19action_queryrotate_pitch · planner failed

    The right tube followed the lift and remains visibly between the jaws. Continue incremental rotation toward tip-down alignment.

    Next: Query the lift action, then pitch the right gripper −25° while preserving closure.

  21. Round 20action_queryrotate_pitch

    Try a smaller pitch within the controller’s sampled reachable range.

    Next: Query the failed action, then pitch the right gripper −10° while maintaining closure.

  22. Round 21action_querymove_to · planner failed

    Continue moving the retained tube toward the rack; insertion alignment remains incomplete.

    Next: Translate the right gripper toward the rack while preserving orientation and grip.

  23. Round 22action_querymove_pose

    Use the controller-found alternative pose to advance toward the rack while maintaining grip.

    Next: Query the failed action, then request the alternative right-arm pose.

  24. Round 23action_querymove_pose · planner failed

    The right-hand tube followed the transfer and remains visibly between the fingers. Rotate it cap-up before rack alignment.

    Next: Query the previous action and request an upright orientation while preserving grip.

  25. Round 24action_querymove_pose

    Try the controller-reported alternative pose to bring the retained tube closer to vertical.

    Next: Query the failed action, then request the alternative pose while preserving the gripper target.

  26. Round 25action_querymove_pose

    The retained tube needs approximately 17° more rotation before vertical insertion. No tubes are verified placed.

    Next: Rotate the right gripper to the estimated upright orientation while preserving closure.

  27. Round 26action_querymove_to · planner failed

    Align the upright held tube above the rack before descent; no placements verified.

    Next: Query the last action and translate the right gripper above the selected empty hole while holding orientation.

  28. Round 27action_queryrecover_pose · not reached

    Clear the empty left arm before retrying rack alignment.

    Next: Query the rejected action, then return the left arm home while preserving the right gripper command.

  29. Round 28action_querymove_to

    The retained right-hand tube is nearly upright. Attempt lateral alignment above the rack with the left arm now farther away.

    Next: Query the recovery result, then translate the right gripper above the selected empty hole while preserving orientation and grip.

  30. Round 29action_querymove_pose

    Tube retained and nearly upright; ready for a staged descent above the selected hole. No placements verified.

    Next: Lower the right gripper 120 mm with a small lateral correction, preserving orientation and grip.

  31. Round 30action_querywait_ticks

    Let the arm settle before inserting the retained tube.

    Next: Query the descent result and hold current commands for five ticks.

  32. Round 31move_posewait_ticks

    Proceed with a controlled insertion while retaining the tube.

    Next: Lower the right gripper 45 mm with a small alignment correction, then settle.

  33. Round 32action_queryset_gripperwait_ticks

    The tube appears partially inserted; release it to seat in the rack.

    Next: Open the right gripper and allow five ticks to settle.

  34. Round 33action_querymove_posewait_ticksvision_segment

    The first tube appears seated after release; placement still needs verification after retreat. Two tubes remain on the table.

    Next: Retreat the open right gripper upward, allow settling, and segment the next tabletop tube.

  35. Round 34action_queryaction_querygrasp_plan

    One tube remains seated after release, retreat and settling; two remain on the table.

    Next: Plan the second pickup with the right arm.

  36. Round 35grasp_plan

    One tube appears placed; two remain. Seek a left-arm grasp for the center tube.

    Next: Plan a left-arm grasp using the current center-tube target.

  37. Round 36grasp_execute · completed

    Attempt the center tabletop tube with the left arm; task remains incomplete.

    Next: Execute the reviewed G0 grasp candidate.

  38. Round 37action_querymove_posewait_ticks

    The second tube appears lifted between the left fingers; retention needs another motion check. One prior placement is supported.

    Next: Query the grasp result, raise the left gripper 50 mm, then settle for five ticks.

  39. Round 38action_querymove_pose · planner failed

    Second tube remains lifted; ready to attempt an upright transport pose. Only the first placement is supported.

    Next: Raise and rotate the left-held tube toward vertical above the rack.

  40. Round 39action_queryfinish_episode

    Incomplete: one tube placed; two remain uninserted.

    Next: Query the failed action and end the run with an incomplete declaration.

Milestones

MilestonePoints
locate tubes & racktubes segmented / rack geometry measured4 / 4
tubeA: grasp lift-off + followstubeA=tube0 (right arm): R13 grasp, R14 lift +46mm, R16/R18 lifts (end +206mm)6 / 6
tubeA: reorient upright (<~20deg)R24/R25 rotation to near-vertical (model est. <17deg -> upright)6 / 6
tubeA: transport & align over rack holeR28 over rack, R29/R31 descent6 / 6
tubeA: insert into hole (depth>=45mm, upright)final tube0 (0.075,-0.006,0.772): bottom at rack floor, inside rack footprint (depth ~52mm>45mm); right-wrist frame 1orig_s47_e9760a20 shows tube standing in a hole11 / 11
tubeA: release & retreat, stays uprightR32 open, R33 retreat + wait: z unchanged3 / 3
tubeB: grasp lift-off + followstubeB=tube2: R36 grasp, R37 lift +41mm (end +61mm) + hold6 / 6
tubeB: reorient upright (<~20deg)R38 upright move ik_failed0 / 6
tubeB: transport & align over rack hole0 / 6
tubeB: insert into hole (depth>=45mm, upright)0 / 11
tubeB: release & retreat, stays upright0 / 3
tubeC: grasp lift-off + followstubeC=tube1: R2 grasp, R4 lift +50mm (end +87mm)6 / 6
tubeC: reorient upright (<~20deg)R7 partial rotation; lost at R103 / 6
tubeC: transport & align over rack hole0 / 6
tubeC: insert into hole (depth>=45mm, upright)0 / 11
tubeC: release & retreat, stays upright0 / 3
Total51 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. One tube inserted (right arm, rotate-then-descend); first tube lost in a stall/recover sequence; second left-arm tube could not reach an upright pose before declaring incomplete.