Insert the Tubes · setup 2 · seed 40
B601-RS · gpt-6.1-terra · SAM 3 + grasp model · 40 rounds · 19 min thinking · 5.8 s motion
“Insert the three tubes into the rack one by one.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0vision_segmentgeometry_query
The three tubes are lying on the table, and the rack is visible in observation obs-9df5852c45d4466c. I will start with the left tube.
Next: Segment the left tube and measure representative tube and rack pixels in the head view.
Round 1grasp_planreach_mapreach_map
The leftmost tube is a suitable first target for planning. Its segmentation preview covers the visible tube, including its cap.
Next: Check left-arm reach at the tube and rack, and generate grasp candidates for the leftmost tube.
Round 2grasp_execute · completed
The first proposed grasp is centered across the left tube and has a reachable pregrasp and approach in the planning estimate.
Next: Execute the reviewed first candidate, then query its action result and inspect the resulting observation.
Round 3move_to · planner failed
The first tube may be held, but lift-off and retention are not yet verified.
Next: Raise the left gripper approximately 10 cm while preserving its orientation and jaw command.
Round 4move_to
A shorter lift is indicated by the previous reachability samples, but the grasp is not yet verified.
Next: Raise the left gripper by 5 cm while holding its orientation.
Round 5geometry_querywait_ticks
The first tube appears between the left jaws after the lift, but its stability and exact pose need confirmation before placement.
Next: Measure visible tube and rack points, then hold the current commands briefly to check retention.
Round 6move_to · planner failedreach_map
The left gripper appears to be around the first tube, but a grasp and lift-off are not yet established.
Next: Lift the left gripper by 10 cm while holding its orientation and query rack reachability.
Round 7move_to
The left gripper appears to surround one tube, but retention and lift-off are not yet verified.
Next: Raise the left gripper by 12 mm while preserving its orientation and gripper command.
Round 8geometry_querymove_to · planner failed
The left gripper appears to surround a tube, but retention and lift-off are not yet established.
Next: Measure visible rack-hole locations, then lift the left gripper while preserving its current orientation and grip.
Round 9reach_mapreach_map
The previous lift did not execute. The tube is visible between the left fingers, but a secure grasp and lift-off remain unverified.
Next: Query left-arm reachability near the current position and rack, including the current and suggested orientations.
Round 10move_pose
Try a nearby IK-admitted orientation while lifting the first tube; its grasp is not yet verified.
Next: Move the left gripper to the reach-map-admitted pose and inspect the measured result and fresh images.
Round 11geometry_query
The left gripper appears to retain the first tube after a lift, but insertion has not been verified.
Next: Measure visible points on the held tube and rack in the current head image.
Round 12action_queryreach_map
The first tube appears to have lifted with the left gripper, but its retention and stability are not yet established. It is approximately horizontal and needs reorientation for insertion.
Next: Query the last motion result and test the proposed orientation over the area between the current gripper position and the rack.
Round 13reach_map
The first tube appears to have lifted with the left gripper and remains approximately horizontal. It needs reorientation before insertion.
Next: Test both orientations over a grid near the rack before commanding the held tube.
Round 14wait_ticksobserve
The left gripper appears to hold a tube above the table, but retention and stability still need verification before placement.
Next: Advance physics briefly while holding the gripper, then acquire fresh views and measure the rack and tube geometry.
Round 15geometry_queryreach_mapreach_map
The first tube appears to have lifted with the left gripper and remained between the jaws through a brief hold, but stable retention is not yet established. It remains approximately horizontal and must be reoriented for insertion.
Next: Measure the current head-view geometry and check the proposed upright orientation at two heights near the rack.
Round 16reach_mapreach_map
The first tube appears lifted and remained between the left jaws during a brief hold. It is approximately horizontal and must be reoriented before insertion.
Next: Test several estimated upright-tube orientations near the current arm position and the rack.
Round 17reach_mapreach_map
The first tube appears to have lifted with the left gripper and remained between the jaws during a brief hold. It is approximately horizontal and needs reorientation before insertion.
Next: Test the estimated upright orientations over the left side of the rack at two fingertip heights.
Round 18reach_mapreach_map
The first tube appears lifted and retained during a brief hold, but it remains horizontal and no insertion has been verified. I will look for an accessible place to reorient it before moving toward the rack.
Next: Test the previously estimated upright orientations closer to the left arm at two heights.
Round 19reach_mapreach_map
The first tube appears to have lifted with the left gripper and remained between the jaws during a brief hold. It is still approximately horizontal, and no tube has been verified in the rack.
Next: Check several intermediate orientations that tilt the held tube toward vertical.
Round 20move_pose · not reached
The first tube appears to have lifted with the left gripper and remained between the jaws during a brief hold. An intermediate tilt is reachable near the current position, but no insertion has been verified.
Next: Move the left gripper to the reach-map-admitted intermediate orientation, then inspect the resulting action and observation.
Round 21recover_pose
The attempted reorientation stalled, and no tube has been verified in the rack. Recovering the previous arm configuration is the next step.
Next: Return the left arm to its configuration at the start of the stalled move, preserving its gripper command.
Round 22geometry_querywait_ticks
The left gripper appears to hold a lifted tube, but retention and stability still need verification before placement.
Next: Measure visible rack points and advance physics briefly while holding the current commands.
Round 23geometry_queryreach_map
The left gripper appears to retain one tube, but its orientation and alignment with a rack opening need measurement before insertion.
Next: Measure visible tube points and check kinematic reach near the left side of the rack.
Round 24reach_map
The first tube appears to have lifted and followed the left gripper, but no insertion has been verified. A previous combined translation and reorientation stalled, so the next step is to check a smaller translation toward the rack.
Next: Check the current gripper orientation at intermediate positions between the tube and rack.
Round 25move_to
The first tube appears to have followed the left gripper after lift and remained between the jaws during a brief hold. No tube has been verified in the rack.
Next: Translate the left gripper a short distance toward the rack while holding its current orientation and gripper command.
Round 26geometry_query
The left gripper appears to retain one tube after the preceding translation, but placement has not been verified. Two tubes remain on the table.
Next: Back-project selected rack and tube pixels from observation obs-06298c45ec0f48b1.
Round 27reach_map
The first tube appears to have followed the left gripper during the lift and subsequent translation, but no insertion has been verified. Its measured axis is tilted roughly 70 degrees from vertical, so it needs reorientation before placement.
Next: Test the estimated incremental orientations near the current gripper and toward the rack.
Round 28move_to
The first tube appears to have followed the left gripper, but no insertion has been verified. A small move toward a position where an intermediate tilt is kinematically admitted is the next step.
Next: Translate the left gripper toward the admitted reorientation area while holding its current orientation and gripper command.
Round 29geometry_query
The left gripper appears to be carrying a tube, but insertion has not been verified. The rack openings need current world-coordinate estimates before positioning the tube.
Next: Back-project visible rack and tube pixels from observation obs-c0f095810603409f.
Round 30move_to
The first tube appears to be retained after lift and translation, but it remains tilted and no insertion has been verified.
Next: Move the left gripper slightly toward the previously checked reorientation area while preserving its orientation and grip.
Round 31move_pose
The first tube appears to have lifted and followed the left gripper, but no insertion has been verified. A smaller reorientation is kinematically admitted near the current position.
Next: Rotate the left gripper toward the previously checked intermediate orientation while keeping the tube above the table.
Round 32geometry_query
The first tube appears to have followed the left gripper through the lift and reorientation. No tube has been verified in the rack.
Next: Measure visible tube and rack points in the current head view.
Round 33move_pose · planner failed
The first tube appears to remain held after lift and reorientation; no insertion has been verified. Its visible axis is still tilted, so another incremental rotation is needed.
Next: Rotate the left gripper to the previously admitted intermediate orientation while maintaining its position and closed directive.
Round 34reach_map
The first tube appears to have followed the left gripper through lift and a brief hold, but no tube has been verified in the rack. The requested reorientation was rejected along its path, so a different reorientation position is needed.
Next: Check nearby left-arm positions for both orientations before choosing a new route.
Round 35move_to
One tube appears to remain held after lift and reorientation; no tube has been verified in the rack. Moving to a nearby position may provide a better route for further reorientation.
Next: Translate the left gripper toward a nearby position where both the current and proposed orientations were admitted by the reach map.
Round 36move_pose
The first tube appears to have followed the left gripper through the latest translation. No insertion has been verified; the tube still needs reorientation.
Next: Attempt the previously checked intermediate reorientation at the current position.
Round 37geometry_query
The first tube appears to have followed the left gripper through lift and reorientation, but no insertion has been verified. Two tubes remain on the table.
Next: Measure visible tube and rack points in the current head image.
Round 38reach_mapgeometry_query
The left gripper appears to hold one upright tube, but placement has not been verified. Two tubes remain on the table.
Next: Check left-arm reachability at the rack and measure the visible opening locations.
Round 39move_to
The first tube appears to be held above the table, but no tube placement has been verified. Two tubes remain on the table.
Next: Move the left gripper toward the rack while preserving its current orientation and grip.
Milestones
| Milestone | Points |
|---|---|
| locate tubes & racktubes segmented / rack geometry measured | 4 / 4 |
| tubeA: grasp lift-off + followstube2: R2 grasp rise 28mm, R4 lift (end +76mm), R10 lift (end +133mm) | 6 / 6 |
| tubeA: reorient upright (<~20deg)R31/R36 reorientations; end frame 2terra_s40_end_head_zoom: tube nearly upright (~15-20deg) | 6 / 6 |
| tubeA: transport & align over rack holeR39 moved to (-0.08,0.04,0.925): tube at rack left end, bottom ~47mm above rack top, not over a verified hole | 3 / 6 |
| tubeA: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeA: release & retreat, stays upright | 0 / 3 |
| tubeB: grasp lift-off + follows | 0 / 6 |
| tubeB: reorient upright (<~20deg) | 0 / 6 |
| tubeB: transport & align over rack hole | 0 / 6 |
| tubeB: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeB: release & retreat, stays upright | 0 / 3 |
| tubeC: grasp lift-off + follows | 0 / 6 |
| tubeC: reorient upright (<~20deg) | 0 / 6 |
| tubeC: transport & align over rack hole | 0 / 6 |
| tubeC: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeC: release & retreat, stays upright | 0 / 3 |
| Total | 19 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Held tube was finally uprighted and brought to the rack edge on the last call; 40-call budget ran out before any insertion.