Insert the Tubes · setup 3 · seed 47

B601-RS · gpt-6-astra · SAM 3 + grasp model · 39 rounds · 43 min thinking · 8.4 s motion

Goal not reachedProgress 16RoboDojo reward 0

“Insert the three tubes into the rack one by one.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_segmentgeometry_query

    Measure tube axes and rack openings before selecting the first grasp.

    Next: Segment the three tubes and back-project selected tube and rack pixels.

  2. Round 1reach_mapgrasp_plan

    Begin with the leftmost tube using the left arm.

    Next: Map reachability at tube height and request grasp candidates for T0.

  3. Round 2grasp_execute · completed

    Attempt the leftmost tube using the reviewed candidate with the highest contact position.

    Next: Execute grasp-6e7109d746035e77692bc364.

  4. Round 3move_pose · planner failedwait_ticks

    The first tube appears lifted; verify retention before reorienting it.

    Next: Raise the left gripper 10 cm with its orientation and closure preserved, then briefly settle.

  5. Round 4reach_mapreach_map

    Check reachable lift and reorientation poses before further motion.

    Next: Map reachability using the measured gripper orientation and a depth-derived cap-up orientation.

  6. Round 5action_querymove_to

    Proceed with a 50 mm lift to test retention before reorientation.

    Next: Query the previous action, then lift the left gripper while preserving orientation and closure.

  7. Round 6reach_mapreach_map

    The first tube followed the lift and remains between the jaws; upright insertion planning can proceed.

    Next: Check reachability before rotating or transporting the held tube.

  8. Round 7reach_mapreach_map

    The first tube followed the lift; a reachable upright orientation is still needed.

    Next: Test eight upright yaw orientations at two heights.

  9. Round 8reach_mapreach_map

    The first tube followed the lift, but its upright pose still needs a reachable transfer path.

    Next: Test upright yaw variants at lower transfer heights.

  10. Round 9reach_map

    The first tube followed the lift, but an upright transport pose remains unresolved. No tubes are placed.

    Next: Test upright orientations in the closer workspace using reach_map.

  11. Round 10reach_mapreach_map

    The current grip does not permit the tested upright poses. Check a right-arm regrasp before moving the tube.

    Next: Test opposite-side grasp orientations near a central handoff position and corresponding upright orientations near the rack.

  12. Round 11reach_mapreach_map

    A regrasp is needed for the tested insertion poses; check a jointly reachable handoff orientation.

    Next: Test rotated holding and regrasp orientations with reach_map.

  13. Round 12reach_mapreach_map

    The first tube remains lifted; no tube is inserted. The tested handoff poses lack a compatible left-arm pose.

    Next: Check a closer handoff region with reach_map before moving.

  14. Round 13move_poseobserve

    Stage the first tube centrally for regrasp. No tubes are inserted.

    Next: Move the left arm to the admitted central pose while preserving closure, then observe.

  15. Round 14reach_mapwait_ticksobserve

    The first tube remains visibly retained; no tubes are inserted. Check a cap-side right-arm regrasp.

    Next: Test regrasp orientations, briefly settle the arms, then observe.

  16. Round 15reach_mapreach_map

    The first tube remains between the left fingers; no tube has been inserted. Check a higher handoff position with the tube rotated toward the right arm.

    Next: Query both arms’ reachability before moving the held tube.

  17. Round 16reach_mapreach_map

    No tube is inserted. A compatible two-arm handoff pose is still needed.

    Next: Check matched left holding and right regrasp regions with reach_map.

  18. Round 17move_poseobserve

    Use an admitted left-arm pose to stage the first tube for regrasp.

    Next: Move the left arm to the reach-map-admitted pose, preserving its gripper target, then observe.

  19. Round 18reach_map

    The first tube remains between the left fingers; no tube has been inserted.

    Next: Test regrasp orientations with reach_map before moving the right arm.

  20. Round 19move_pose · planner failed

    Proceed to a right-arm staging pose for the first tube’s handoff; no tubes are inserted yet.

    Next: Move the open right gripper 60 mm back along the admitted regrasp approach.

  21. Round 20reach_mapreach_map

    Check a shorter staging approach for the first tube’s handoff. No tubes are inserted yet.

    Next: Test the original and suggested orientations with reach_map before moving.

  22. Round 21move_pose

    Move the open right gripper to the admitted staging pose for the first tube’s handoff. No tubes are inserted yet.

    Next: Stage the right fingertip at [0.014,-0.336,0.910] m using the reach_map-admitted custom orientation.

  23. Round 22move_pose

    Approach the first tube for transfer; no insertion is verified.

    Next: Move the open right gripper to the updated tube center while the left maintains its grip.

  24. Round 23set_gripper · not reached

    The right gripper is positioned for a transfer attempt; no tube insertion is verified.

    Next: Close the right gripper while maintaining the left grip.

  25. Round 24set_gripper

    Ready to attempt transfer to the right gripper; no tubes are inserted.

    Next: Open the left gripper while preserving the right grip.

  26. Round 25move_pose · planner failed

    Clear the open left gripper before testing right-hand retention. No tubes are inserted yet.

    Next: Retract the left gripper 80 mm along its negative approach axis.

  27. Round 26reach_mapreach_map

    Clear the open left gripper before testing right-hand retention. No tubes are verified inserted.

    Next: Check both poses with reach_map before commanding motion.

  28. Round 27move_pose

    Use the admitted left-arm retreat pose to clear the tube before testing right-hand retention. No tubes are verified inserted.

    Next: Move the open left gripper upward and away using the reach_map-admitted orientation.

  29. Round 28move_pose

    Proceed with a short right-arm lift to verify tube retention after handoff.

    Next: Raise the right gripper 35 mm while preserving orientation and closure.

  30. Round 29reach_mapreach_map

    The tube appears retained after the right-arm lift; upright reachability must be checked before rotation.

    Next: Test upright orientation variants at staging and rack positions.

  31. Round 30reach_mapreach_map

    The held tube needs a reachable cap-up orientation before insertion.

    Next: Test eight upright yaw variants at fingertip heights of 0.94 m and 0.92 m.

  32. Round 31reach_mapreach_map

    The first tube remains suspended, but no tube is inserted.

    Next: Check upright orientations above the nearer right-hand hole at approach and insertion heights.

  33. Round 32reach_mapreach_map

    The first tube remains held; no tube has been inserted.

    Next: Test eight nearby orientations at approach and insertion heights.

  34. Round 33move_pose

    Proceed to the admitted staging pose above the rack; no tubes are placed yet.

    Next: Transport the right-held tube above the rack with the admitted custom_2 orientation.

  35. Round 34vision_ground

    The transported tube was lost; no insertion is verified.

    Next: Locate the tube to the right of the rack for a new pickup.

  36. Round 35action_querygrasp_planreach_map

    No tube insertion is verified. Plan a fresh right-arm grasp of the tube beside the rack.

    Next: Query the last action, generate grasp candidates, and check reachability before any motion.

  37. Round 36grasp_execute · completed

    No insertion is verified. Attempt a fresh pickup of the tube right of the rack.

    Next: Execute reviewed candidate G0, which has the greatest support clearance among the three returned candidates.

  38. Round 37move_posereach_map

    A tube is visibly between the right fingers; stable retention remains unverified. No tubes are verified inserted.

    Next: Lift the right gripper 50 mm, then test candidate upright orientations above the rack.

Milestones

MilestonePoints
locate tubes & racktubes segmented / rack geometry measured4 / 4
tubeA: grasp lift-off + followstubeA=tube1: R2 grasp, R5 lift +49mm, handed to right arm R23-R28 (right lift +23mm, held)6 / 6
tubeA: reorient upright (<~20deg)never uprighted; R33 transfer lost tube0 / 6
tubeA: transport & align over rack hole0 / 6
tubeA: insert into hole (depth>=45mm, upright)0 / 11
tubeA: release & retreat, stays upright0 / 3
tubeB: grasp lift-off + followstubeB=tube0: R36 grasp, R37 lift +46mm (end +72mm)6 / 6
tubeB: reorient upright (<~20deg)0 / 6
tubeB: transport & align over rack hole0 / 6
tubeB: insert into hole (depth>=45mm, upright)0 / 11
tubeB: release & retreat, stays upright0 / 3
tubeC: grasp lift-off + follows0 / 6
tubeC: reorient upright (<~20deg)0 / 6
tubeC: transport & align over rack hole0 / 6
tubeC: insert into hole (depth>=45mm, upright)0 / 11
tubeC: release & retreat, stays upright0 / 3
Total16 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Successful left->right handoff (only one in the tube runs) but the next staging move flung the tube; re-grasped a second tube just before the budget.