Insert the Tubes · setup 4 · seed 40

B601-RS · gpt-6-astra · no perception models · 40 rounds · 40 min thinking · 8.5 s motion

Goal not reachedProgress 19RoboDojo reward 0

“Insert the three tubes into the rack one by one.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0reach_map

    Begin with the isolated left tube using the left arm.

    Next: Check low grasp reachability before moving.

  2. Round 1reach_mapreach_map

    Measure reachability before the first low grasp and subsequent tube reorientation.

    Next: Query left-arm grasp and upright transport orientations.

  3. Round 2move_pose · planner failed

    Begin the left tube pickup using the admitted tilted approach.

    Next: Move the left gripper above the selected contact point.

  4. Round 3move_pose

    Use the IK-admitted alternative orientation for the free-space staging move.

    Next: Move the left gripper above the left tube with the alternative orientation.

  5. Round 4move_pose

    Proceed to the previously reach-mapped low grasp pose for the left tube.

    Next: Lower the open left gripper to the planned contact pose.

  6. Round 5set_gripper · not reachedset_gripper · not reachedset_gripper · not reachedset_gripper · not reached

    The first tube is between the open fingers; proceed with incremental closure.

    Next: Apply four controller-limited close increments to the left gripper.

  7. Round 6move_to

    Test the first tube’s grasp with a 60 mm vertical lift.

    Next: Lift the left gripper while preserving orientation and its retained closure target.

  8. Round 7reach_mapwait_ticks

    The first tube lifted and followed the left gripper; settled stability still needs verification.

    Next: Check upright reachability above the rack and hold the current grasp for five physics ticks.

  9. Round 8move_pose · plan rejected

    The first tube shows stable retention during the short hold; proceed to upright staging above the rack.

    Next: Move the left gripper to the reach-map-admitted upright staging pose, preserving its grip.

  10. Round 9move_pose

    Use the controller’s reachable, partially rotated staging pose before attempting upright alignment.

    Next: Move the left arm to alternate staging while preserving its grip.

  11. Round 10move_pose · plan rejected

    The first tube remains held; complete its upright reorientation before insertion.

    Next: Move the left arm to the previously reach-map-admitted upright staging pose, preserving grip.

  12. Round 11reach_map

    Check alternative upright orientations before further motion.

    Next: Query a higher staging grid with eight upright-tube orientation candidates.

  13. Round 12move_pose · plan rejected

    Try the higher, yaw-adjusted upright staging pose admitted by round-12 reach_map.

    Next: Move the left arm to the higher staging pose while preserving its grip.

  14. Round 13reach_map

    Find a staging position nearer the robot before attempting further upright rotation.

    Next: Query reach_map while preserving the existing grip.

  15. Round 14move_to

    Translate the held first tube to the admitted staging point before further reorientation.

    Next: Translate the left gripper while preserving its orientation and grip.

  16. Round 15reach_map

    Check incremental rotations and alternative upright orientations before moving again.

    Next: Query reach_map; preserve the existing grip.

  17. Round 16move_pose · plan rejected

    Proceed with an admitted 30-degree reorientation step; the first tube is not yet insertion-ready.

    Next: Move left arm to the selected staging pose, preserving its grip.

  18. Round 17move_pose

    Take only the admitted first quarter of the rejected route; the tube is not upright enough for insertion.

    Next: Translate 36.7 mm and rotate 7.5 degrees while retaining the grip.

  19. Round 18reach_map

    Check a wrist roll that moves away from the joint limit before further upright alignment.

    Next: Query reach_map at the raised staging position for three negative wrist rolls.

  20. Round 19rotate_wrist

    Proceed with the reach-map-admitted −60° wrist roll to gain wrist joint margin before upright alignment.

    Next: Roll the left wrist −60° while preserving its grip.

  21. Round 20reach_map

    The first tube remains retained; upright alignment is still required before insertion.

    Next: Query reach_map before another reorientation.

  22. Round 21rotate_wrist

    Continue reorientation before approaching the rack; insertion is not yet possible.

    Next: Roll the left wrist −180° with the current grip retained, using the reach-map-admitted orientation.

  23. Round 22reach_map

    The tube followed the wrist roll, but is not upright or ready for insertion.

    Next: Check candidate upright orientations with reach_map while retaining the current grip.

  24. Round 23reach_map

    The held tube is not upright; further reach planning is needed before insertion.

    Next: Test eight upright yaw alternatives while retaining the existing grip.

  25. Round 24move_pose · plan rejected

    Proceed to the newly admitted upright staging pose.

    Next: Move the left arm to raised staging while preserving its grip.

  26. Round 25reach_map

    Plan a smaller reorientation through an intermediate joint configuration; no insertion is verified.

    Next: Query reach_map for the first intermediate pose while preserving the existing grip.

  27. Round 26move_pose · planner failed

    Try a smaller free-space reorientation step while retaining the grip. No tube insertion is verified.

    Next: Command the smaller joint-derived pose, then inspect terminal feedback and RGB-D.

  28. Round 27reach_map

    Check a different staging region before further reorientation; no tube insertion is verified.

    Next: Query reach_map while retaining the current grip.

  29. Round 28move_to

    Move to the reachable higher staging point before replanning tube orientation.

    Next: Translate the left gripper while preserving its orientation and closing target.

  30. Round 29reach_map

    The first tube followed the higher staging move; upright alignment is still needed.

    Next: Query upright orientation alternatives before moving.

  31. Round 30move_pose · plan rejected

    Attempt the admitted upright staging pose while retaining the grip. No tubes are yet verified inserted.

    Next: Reorient the left gripper at the selected high staging point.

  32. Round 31move_pose

    Take the short reorientation admitted by the last route diagnostic, then reassess.

    Next: Move to the first-quarter waypoint while retaining the current grip.

  33. Round 32move_pose · planner failed

    The first tube remains retained, but is not upright or inserted.

    Next: Continue one-third of the remaining motion toward the previously reach-map-admitted upright staging pose, preserving grip.

  34. Round 33reach_map

    The current reorientation route is unsuitable; test upright poses in a different workspace before moving.

    Next: Query reach_map while preserving the existing grip.

  35. Round 34move_pose · plan rejected

    Try the newly admitted upright pose nearer the robot.

    Next: Move the left gripper to the reach-map-admitted endpoint while retaining its closing target.

  36. Round 35move_pose

    Try the controller-reported alternative staging orientation before insertion.

    Next: Move the left arm to the alternative pose while retaining its grip.

  37. Round 36reach_map

    The first tube followed the gripper through reorientation; no insertion is verified.

    Next: Test upright and current orientations above the rack before descending.

  38. Round 37move_to

    Move the held tube to staging above the rack; alignment is insufficient for insertion.

    Next: Translate the left gripper to the reach-map-admitted staging position, retaining orientation and grip.

  39. Round 38reach_map

    The first tube remains retained, but alignment is insufficient for insertion. No placement is verified.

    Next: Check upright orientations at a lower staging height before moving.

  40. Round 39wait_ticks

    Task incomplete: no tube insertion verified. Run limit is imminent.

    Next: Hold for five ticks and inspect the returned observation before stopping.

Milestones

MilestonePoints
locate tubes & rackmanual (reach_map + wrist views)4 / 4
tubeA: grasp lift-off + followstube2: R5 closure, R6 lift +59mm, R7 hold, held to end6 / 6
tubeA: reorient upright (<~20deg)R35 reoriented; end frame 4nosam_s40_end_head_zoom: tube nearly upright over rack6 / 6
tubeA: transport & align over rack holeR37 to rack: tube at (-0.066,-0.005,0.844), bottom ~20mm above rack top, model judged alignment insufficient3 / 6
tubeA: insert into hole (depth>=45mm, upright)0 / 11
tubeA: release & retreat, stays upright0 / 3
tubeB: grasp lift-off + follows0 / 6
tubeB: reorient upright (<~20deg)0 / 6
tubeB: transport & align over rack hole0 / 6
tubeB: insert into hole (depth>=45mm, upright)0 / 11
tubeB: release & retreat, stays upright0 / 3
tubeC: grasp lift-off + follows0 / 6
tubeC: reorient upright (<~20deg)0 / 6
tubeC: transport & align over rack hole0 / 6
tubeC: insert into hole (depth>=45mm, upright)0 / 11
tubeC: release & retreat, stays upright0 / 3
Total19 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Long reorientation search (7 plan_rejected/ik_failed) with one tube; got it near-upright over the rack on the last physical step; budget ended.