Insert the Tubes · setup 4 · seed 40
B601-RS · gpt-6-astra · no perception models · 40 rounds · 40 min thinking · 8.5 s motion
“Insert the three tubes into the rack one by one.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0reach_map
Begin with the isolated left tube using the left arm.
Next: Check low grasp reachability before moving.
Round 1reach_mapreach_map
Measure reachability before the first low grasp and subsequent tube reorientation.
Next: Query left-arm grasp and upright transport orientations.
Round 2move_pose · planner failed
Begin the left tube pickup using the admitted tilted approach.
Next: Move the left gripper above the selected contact point.
Round 3move_pose
Use the IK-admitted alternative orientation for the free-space staging move.
Next: Move the left gripper above the left tube with the alternative orientation.
Round 4move_pose
Proceed to the previously reach-mapped low grasp pose for the left tube.
Next: Lower the open left gripper to the planned contact pose.
Round 5set_gripper · not reachedset_gripper · not reachedset_gripper · not reachedset_gripper · not reached
The first tube is between the open fingers; proceed with incremental closure.
Next: Apply four controller-limited close increments to the left gripper.
Round 6move_to
Test the first tube’s grasp with a 60 mm vertical lift.
Next: Lift the left gripper while preserving orientation and its retained closure target.
Round 7reach_mapwait_ticks
The first tube lifted and followed the left gripper; settled stability still needs verification.
Next: Check upright reachability above the rack and hold the current grasp for five physics ticks.
Round 8move_pose · plan rejected
The first tube shows stable retention during the short hold; proceed to upright staging above the rack.
Next: Move the left gripper to the reach-map-admitted upright staging pose, preserving its grip.
Round 9move_pose
Use the controller’s reachable, partially rotated staging pose before attempting upright alignment.
Next: Move the left arm to alternate staging while preserving its grip.
Round 10move_pose · plan rejected
The first tube remains held; complete its upright reorientation before insertion.
Next: Move the left arm to the previously reach-map-admitted upright staging pose, preserving grip.
Round 11reach_map
Check alternative upright orientations before further motion.
Next: Query a higher staging grid with eight upright-tube orientation candidates.
Round 12move_pose · plan rejected
Try the higher, yaw-adjusted upright staging pose admitted by round-12 reach_map.
Next: Move the left arm to the higher staging pose while preserving its grip.
Round 13reach_map
Find a staging position nearer the robot before attempting further upright rotation.
Next: Query reach_map while preserving the existing grip.
Round 14move_to
Translate the held first tube to the admitted staging point before further reorientation.
Next: Translate the left gripper while preserving its orientation and grip.
Round 15reach_map
Check incremental rotations and alternative upright orientations before moving again.
Next: Query reach_map; preserve the existing grip.
Round 16move_pose · plan rejected
Proceed with an admitted 30-degree reorientation step; the first tube is not yet insertion-ready.
Next: Move left arm to the selected staging pose, preserving its grip.
Round 17move_pose
Take only the admitted first quarter of the rejected route; the tube is not upright enough for insertion.
Next: Translate 36.7 mm and rotate 7.5 degrees while retaining the grip.
Round 18reach_map
Check a wrist roll that moves away from the joint limit before further upright alignment.
Next: Query reach_map at the raised staging position for three negative wrist rolls.
Round 19rotate_wrist
Proceed with the reach-map-admitted −60° wrist roll to gain wrist joint margin before upright alignment.
Next: Roll the left wrist −60° while preserving its grip.
Round 20reach_map
The first tube remains retained; upright alignment is still required before insertion.
Next: Query reach_map before another reorientation.
Round 21rotate_wrist
Continue reorientation before approaching the rack; insertion is not yet possible.
Next: Roll the left wrist −180° with the current grip retained, using the reach-map-admitted orientation.
Round 22reach_map
The tube followed the wrist roll, but is not upright or ready for insertion.
Next: Check candidate upright orientations with reach_map while retaining the current grip.
Round 23reach_map
The held tube is not upright; further reach planning is needed before insertion.
Next: Test eight upright yaw alternatives while retaining the existing grip.
Round 24move_pose · plan rejected
Proceed to the newly admitted upright staging pose.
Next: Move the left arm to raised staging while preserving its grip.
Round 25reach_map
Plan a smaller reorientation through an intermediate joint configuration; no insertion is verified.
Next: Query reach_map for the first intermediate pose while preserving the existing grip.
Round 26move_pose · planner failed
Try a smaller free-space reorientation step while retaining the grip. No tube insertion is verified.
Next: Command the smaller joint-derived pose, then inspect terminal feedback and RGB-D.
Round 27reach_map
Check a different staging region before further reorientation; no tube insertion is verified.
Next: Query reach_map while retaining the current grip.
Round 28move_to
Move to the reachable higher staging point before replanning tube orientation.
Next: Translate the left gripper while preserving its orientation and closing target.
Round 29reach_map
The first tube followed the higher staging move; upright alignment is still needed.
Next: Query upright orientation alternatives before moving.
Round 30move_pose · plan rejected
Attempt the admitted upright staging pose while retaining the grip. No tubes are yet verified inserted.
Next: Reorient the left gripper at the selected high staging point.
Round 31move_pose
Take the short reorientation admitted by the last route diagnostic, then reassess.
Next: Move to the first-quarter waypoint while retaining the current grip.
Round 32move_pose · planner failed
The first tube remains retained, but is not upright or inserted.
Next: Continue one-third of the remaining motion toward the previously reach-map-admitted upright staging pose, preserving grip.
Round 33reach_map
The current reorientation route is unsuitable; test upright poses in a different workspace before moving.
Next: Query reach_map while preserving the existing grip.
Round 34move_pose · plan rejected
Try the newly admitted upright pose nearer the robot.
Next: Move the left gripper to the reach-map-admitted endpoint while retaining its closing target.
Round 35move_pose
Try the controller-reported alternative staging orientation before insertion.
Next: Move the left arm to the alternative pose while retaining its grip.
Round 36reach_map
The first tube followed the gripper through reorientation; no insertion is verified.
Next: Test upright and current orientations above the rack before descending.
Round 37move_to
Move the held tube to staging above the rack; alignment is insufficient for insertion.
Next: Translate the left gripper to the reach-map-admitted staging position, retaining orientation and grip.
Round 38reach_map
The first tube remains retained, but alignment is insufficient for insertion. No placement is verified.
Next: Check upright orientations at a lower staging height before moving.
Round 39wait_ticks
Task incomplete: no tube insertion verified. Run limit is imminent.
Next: Hold for five ticks and inspect the returned observation before stopping.
Milestones
| Milestone | Points |
|---|---|
| locate tubes & rackmanual (reach_map + wrist views) | 4 / 4 |
| tubeA: grasp lift-off + followstube2: R5 closure, R6 lift +59mm, R7 hold, held to end | 6 / 6 |
| tubeA: reorient upright (<~20deg)R35 reoriented; end frame 4nosam_s40_end_head_zoom: tube nearly upright over rack | 6 / 6 |
| tubeA: transport & align over rack holeR37 to rack: tube at (-0.066,-0.005,0.844), bottom ~20mm above rack top, model judged alignment insufficient | 3 / 6 |
| tubeA: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeA: release & retreat, stays upright | 0 / 3 |
| tubeB: grasp lift-off + follows | 0 / 6 |
| tubeB: reorient upright (<~20deg) | 0 / 6 |
| tubeB: transport & align over rack hole | 0 / 6 |
| tubeB: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeB: release & retreat, stays upright | 0 / 3 |
| tubeC: grasp lift-off + follows | 0 / 6 |
| tubeC: reorient upright (<~20deg) | 0 / 6 |
| tubeC: transport & align over rack hole | 0 / 6 |
| tubeC: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeC: release & retreat, stays upright | 0 / 3 |
| Total | 19 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Long reorientation search (7 plan_rejected/ik_failed) with one tube; got it near-upright over the rack on the last physical step; budget ended.