Insert the Tubes · setup 4 · seed 47
B601-RS · gpt-6-astra · no perception models · 34 rounds · 42 min thinking · 12.2 s motion
“Insert the three tubes into the rack one by one.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0reach_mapreach_map
The tubes lie on the table and require lifting and reorientation before insertion.
Next: Check left-arm reach for a downward grasp and a horizontal approach needed to hold the tube upright.
Round 1reach_mapreach_map
Measure reachability before selecting the first grasp.
Next: Test candidate orientations at both locations.
Round 2move_posereach_map
Begin a staged approach to the left tube while checking insertion-orientation reachability.
Next: Move above the left tube; test upright-carry orientations near the rack.
Round 3move_posereach_map
Proceed with the first tube’s open-jaw contact approach.
Next: Lower the left gripper beside the tube and test insertion-orientation reachability.
Round 4set_gripper · not reachedset_gripper · not reachedreach_map
Begin incremental closure around the first tube; no grasp established.
Next: Apply two capped closure increments and check upright-orientation reach nearer the left arm.
Round 5move_to
Contact is plausible; grasp remains unverified. Proceed with an 80 mm test lift.
Next: Raise the left gripper while preserving its orientation and closing drive.
Round 6wait_ticksreach_map
Lift-off and following are observed; grasp stability still needs checking.
Next: Hold briefly, then test upright-carry orientations above the rack.
Round 7move_pose · not reached
The first tube shows lift-off, following and short-term stability; proceed with upright transport.
Next: Move the left gripper to the reach-map-admitted upright carrying pose above the rack.
Round 8action_queryrecover_pose
The first tube’s grasp may have been lost; no insertion is verified.
Next: Query the stalled action and recover the left arm to its previous configuration.
Round 9action_queryreach_mapset_gripper
The first tube was dropped during the failed carry. No insertion is verified.
Next: Check reachability and open the empty left gripper.
Round 10move_pose · planner failed
Approach the dropped tube in stages using a reach-map-admitted orientation.
Next: Move the open left gripper to a standoff above the tube.
Round 11reach_mapreach_map
Check a consistent reachable orientation at both approach and contact heights before moving.
Next: Query reach maps at the dropped tube’s near-cap site.
Round 12reach_mapreach_map
Check a consistent approach orientation before another grasp attempt.
Next: Test tilt35_yaw90 at contact height and tilt20_yaw90 at standoff height.
Round 13move_pose
Use the admitted 35-degree tilted standoff, then reassess before descending.
Next: Move the empty left gripper above the displaced tube.
Round 14move_pose
Proceed with the first tube’s contact approach; no grasp or insertion is verified.
Next: Lower the open left gripper using the previously reach-tested contact orientation.
Round 15set_gripper · not reached
The near-cap body is positioned between the open left jaws; proceed with closure.
Next: Close the left gripper at the measured pose.
Round 16move_pose
Contact is plausible; grasp remains unverified.
Next: Lift to the previously reached standoff, retaining the closing drive.
Round 17set_gripperreach_mapreach_map
The latest grasp failed; retry with jaws perpendicular to the tube and level with the table.
Next: Open the empty left gripper and test revised orientations.
Round 18reach_mapreach_map
Plan a transverse-jaw grasp of the exposed right tube after checking reachability at both heights.
Next: Query right-arm reach maps at fingertip heights 0.784 m and 0.875 m.
Round 19move_pose
Approach the right tube using the admitted standoff orientation; no tube is inserted.
Next: Move the open right gripper above the tube’s near-cap body.
Round 20move_pose
Proceed with the right tube’s contact approach.
Next: Lower the open right gripper using the previously reach-map-admitted contact orientation.
Round 21set_gripper · not reached
Right tube is centered between the open jaws; proceed with closure.
Next: Close the right gripper at its current pose.
Round 22move_pose
Contact is plausible; grasp remains unverified.
Next: Raise the right gripper to its previously reached standoff while retaining closure.
Round 23wait_ticksreach_map
The right tube lifted off and followed the gripper; stability still needs verification.
Next: Hold five ticks and test upright orientations near the rack.
Round 24reach_mapreach_map
The right tube remains lifted and stable during the short hold; no tubes are inserted yet.
Next: Check translation-only carry and in-place upright options before moving.
Round 25move_pose · plan rejected
Reorient the held right tube locally before transporting it to the rack.
Next: Raise and reorient the right gripper to the reach_map-admitted upright pose, retaining its closing drive.
Round 26move_pose
Use the reported reachable intermediate orientation before attempting full upright alignment.
Next: Raise and partially rotate the right gripper while maintaining closure.
Round 27reach_mapreach_map
The right tube remains held and is closer to vertical; no insertion is verified.
Next: Test both waypoints before completing reorientation and transport.
Round 28reach_mapreach_map
The right tube remains lifted and followed the latest reorientation; no tube insertion is verified.
Next: Test upright orientations with different jaw yaws before commanding transport.
Round 29move_pose · plan rejected
Move the held tube to the IK-admitted upright pose above the rack, then inspect before insertion.
Next: Transport the right gripper to the tested overhead pose while retaining its closing directive.
Round 30move_pose
Use the sampled reachable intermediate pose before continuing toward the rack.
Next: Move the right gripper to the intermediate pose while retaining closure.
Round 31recover_pose
The right tube slipped during transport; no insertion is verified.
Next: Withdraw the right arm to its previous measured pose.
Round 32wait_ticks
No tubes are verified inserted; the transported tube was lost.
Next: Hold five ticks, then inspect the updated observation.
Milestones
| Milestone | Points |
|---|---|
| locate tubes & rackmanual (reach_map) | 4 / 4 |
| tubeA: grasp lift-off + followstubeA=tube0 (right): R21 closure, R22 lift +52mm, R23 hold | 6 / 6 |
| tubeA: reorient upright (<~20deg)R26 partial reorientation (+79mm), lost at R30 | 3 / 6 |
| tubeA: transport & align over rack hole | 0 / 6 |
| tubeA: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeA: release & retreat, stays upright | 0 / 3 |
| tubeB: grasp lift-off + followstubeB=tube1 (left): R5 lift +49mm, R6 hold; dropped R7 | 6 / 6 |
| tubeB: reorient upright (<~20deg) | 0 / 6 |
| tubeB: transport & align over rack hole | 0 / 6 |
| tubeB: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeB: release & retreat, stays upright | 0 / 3 |
| tubeC: grasp lift-off + follows | 0 / 6 |
| tubeC: reorient upright (<~20deg) | 0 / 6 |
| tubeC: transport & align over rack hole | 0 / 6 |
| tubeC: insert into hole (depth>=45mm, upright) | 0 / 11 |
| tubeC: release & retreat, stays upright | 0 / 3 |
| Total | 19 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Both grasped tubes slipped out during transport/reorientation (thin near-cap pinch); no tube reached upright.