Insert the Tubes · setup 6 · seed 47

ARX X5 · gpt-6-astra · full object info · 40 rounds · 25 min thinking · 10.6 s motion

Goal not reachedProgress 51RoboDojo reward 0

“Insert the three tubes into the rack one by one.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0scene_truth

    Inspect exact tube axes and rack slots before planning contact.

    Next: Query scene truth, then check grasp and insertion reachability.

  2. Round 1reach_mapreach_map

    Start with the isolated right tube, tube0.

    Next: Check kinematic reach at tube0 and the rack.

  3. Round 2move_pose

    Approach the isolated right tube near its cap.

    Next: Move the right gripper to the admitted downward grasp pose.

  4. Round 3set_gripper · not reachedset_gripper · not reachedset_gripper · not reachedset_gripper · not reached

    The right gripper is positioned for the first tube grasp.

    Next: Close the right gripper in controller-limited increments.

  5. Round 4move_toscene_truth

    Test retention with a small vertical lift; further closure is unwarranted.

    Next: Raise the right gripper 70 mm, then query tube pose.

  6. Round 5reach_mapreach_map

    Tube0 followed the lift; check reachability for upright transport and insertion.

    Next: Test upright poses above the rack and at insertion height.

  7. Round 6move_posescene_truth

    Proceed with upright transport above the rack.

    Next: Move tube0 above the measured opening, then measure its pose.

  8. Round 7wait_ticksscene_truth

    Allow the held tube to settle before insertion.

    Next: Hold briefly, then remeasure tube0.

  9. Round 8reach_mapreach_map

    Tube0 remains retained; correct its 11.2° tilt before insertion.

    Next: Check both corrected poses with reach_map.

  10. Round 9move_posescene_truth

    The corrected orientation is reachable; align tube0 above the rack before insertion.

    Next: Move to the checked alignment pose, then measure tube0.

  11. Round 10move_posescene_truth

    Tube0 is retained and approximately 2.9° from upright; proceed with the first insertion descent.

    Next: Lower 60 mm toward the measured opening, preserving grip and orientation, then measure tube0.

  12. Round 11move_posescene_truth

    Tube0 followed the descent and remains nearly upright. Continue insertion by 20 mm.

    Next: Lower the right gripper 20 mm, then query tube0 pose.

  13. Round 12set_gripperset_gripperset_grippermove_posewait_ticksscene_truth

    Tube0 is inserted far enough to test release.

    Next: Open the right gripper, retreat, and allow settling.

  14. Round 13reach_map

    Tube0 placement is supported; plan tube1 next.

    Next: Query reachability at the low grasp position.

  15. Round 14move_pose

    Proceed with the reach-admitted left-arm approach to tube1.

    Next: Position the open left gripper around tube1 near its cap.

  16. Round 15set_gripper · not reachedset_gripper · not reachedset_gripper · not reachedset_gripper · not reached

    Tube1 is aligned for incremental closure; grasp remains unverified.

    Next: Close the left gripper in four controller-limited increments.

  17. Round 16scene_truthmove_toscene_truth

    Tube1 contact is evident; grasp retention remains unverified. Tube0 was previously verified in the rack.

    Next: Lift the left gripper 70 mm while preserving orientation and closure drive.

  18. Round 17reach_mapreach_map

    Tube1 followed the lift; test reachability before uprighting it above an empty hole.

    Next: Check the left arm at both planned heights.

  19. Round 18move_posewait_ticksscene_truth

    The held tube can be reoriented above the empty left rack opening; both planned heights passed IK checks.

    Next: Move tube1 upright above the rack, settle briefly, then measure its pose.

  20. Round 19reach_mapscene_truth

    Tube1 was dropped during reorientation; recovery is needed.

    Next: Map tube1 grasp reachability and read tube poses.

  21. Round 20reach_mapreach_mapset_gripperset_gripperset_gripperset_gripper

    Tube0 is placed; tube1 was dropped and needs recovery. Check reachability for both remaining tubes before choosing the next grasp.

    Next: Map both grasp targets and open the empty left gripper.

  22. Round 21move_pose · plan rejectedscene_truth

    Proceed with tube2’s reachable pickup; tube1 still needs recovery.

    Next: Move the open left gripper to tube2’s near-cap grasp pose, then inspect.

  23. Round 22move_pose

    Split the rejected approach into smaller motions.

    Next: Move the open left gripper to the reported reachable intermediate pose.

  24. Round 23move_pose · plan rejected

    Continue tube2’s approach from the reached intermediate pose; tube0 remains placed.

    Next: Move the open left gripper to the previously reach-mapped tube2 grasp pose.

  25. Round 24scene_truthreach_map

    Test the symmetric downward grasp orientation before another approach.

    Next: Refresh scene truth and map tube2’s grasp target.

  26. Round 25move_pose · plan rejected

    Separate orientation adjustment from the low approach to tube2.

    Next: Rotate the open left gripper downward at its current position using precision motion.

  27. Round 26move_pose

    Try the reach-mapped downward orientation with world-X jaws for tube2.

    Next: Approach tube2 with open left fingers using the alternative orientation.

  28. Round 27move_poseset_gripper · not reachedset_gripper · not reachedset_gripper · not reachedset_gripper · not reachedscene_truth

    Tube2 is positioned between open fingers; settle the approach and close incrementally.

    Next: Repeat the approach target, then issue four bounded closure commands.

  29. Round 28move_posescene_truth

    Test tube2 retention with a small lift before transport.

    Next: Raise the left gripper 70 mm, preserving orientation and closure drive, then inspect tube poses.

  30. Round 29reach_mapreach_mapmove_pose · planner failedscene_truth

    Tube2 followed the lift, but its grip shifted. Increase clearance before gradual reorientation.

    Next: Map two rotation poses, lift vertically, and remeasure tube2.

  31. Round 30move_posewait_ticksscene_truthobserve

    Use a shorter reachable lift before reorienting tube2.

    Next: Lift left arm 100 mm, settle briefly, then inspect tube2.

  32. Round 31move_posewait_ticksscene_truthobserve

    Tube2 followed the lift and remained suspended during settling. Proceed with partial uprighting.

    Next: Move to the previously reach-mapped half-upright pose, settle, then inspect.

  33. Round 32reach_mapset_gripperset_gripperset_gripperset_gripper

    Tube2 was lost during rotation; one tube remains verified in the rack.

    Next: Map the low grasp orientation and reopen the left gripper.

  34. Round 33move_pose

    Retry tube2 with a transverse near-cap grasp using the reach-map-admitted pose.

    Next: Move the open left gripper to the tube2 grasp pose.

  35. Round 34move_poseset_gripperset_gripperset_gripperset_grippermove_posescene_truth

    Proceed with transverse cap closure and a short lift test.

    Next: Settle the approach, close incrementally, lift 70 mm, and inspect tube motion.

  36. Round 35reach_mapset_gripper

    Tube2 grasp failed; correct the cap contact position.

    Next: Map the corrected low target and open the left gripper.

  37. Round 36move_poseset_gripper · not reachedmove_toscene_truth

    Retry tube2 with the corrected cap-centered grasp; only tube0 placement is verified.

    Next: Approach the corrected target, close, lift 70 mm, and measure tube motion.

  38. Round 37reach_mapreach_map

    Tube2 lifted with the left gripper; reorientation remains unverified.

    Next: Check upright and intermediate orientations before moving.

  39. Round 38move_posewait_ticksscene_truthobserve

    One tube is placed; tube2 is held and tube1 remains on the table.

    Next: Move to the reach-mapped intermediate orientation, settle, and inspect.

  40. Round 39move_posewait_ticksscene_truthobserve

    Tube0 placement is verified. Tube1 remains on the table; tube2 is retained but not ready for insertion.

    Next: Move to the previously reach-mapped upright pose, settle, and inspect before insertion.

Milestones

MilestonePoints
locate tubes & rackscene_truth4 / 4
tubeA: grasp lift-off + followstubeA=tube0: R3 closure, R4 lift +65mm6 / 6
tubeA: reorient upright (<~20deg)R6/R9 upright (model 2.9deg)6 / 6
tubeA: transport & align over rack holeR9 over hole, R10/R11 descent6 / 6
tubeA: insert into hole (depth>=45mm, upright)final (0.072,0.004,0.771) seated; frame 6arx_s47_a178ec19_head_zoom shows tube upright in rack11 / 11
tubeA: release & retreat, stays uprightR12 open, retreat, wait3 / 3
tubeB: grasp lift-off + followstubeB=tube2: R36 regrasp, lift +60mm (earlier R28-R30 grasp lost at R31)6 / 6
tubeB: reorient upright (<~20deg)R38 partial uprighting over rack; R39 dropped onto rack top (z=0.838)3 / 6
tubeB: transport & align over rack hole0 / 6
tubeB: insert into hole (depth>=45mm, upright)0 / 11
tubeB: release & retreat, stays upright0 / 3
tubeC: grasp lift-off + followstubeC=tube1: R15/R16 grasp lift +67mm; dropped R186 / 6
tubeC: reorient upright (<~20deg)0 / 6
tubeC: transport & align over rack hole0 / 6
tubeC: insert into hole (depth>=45mm, upright)0 / 11
tubeC: release & retreat, stays upright0 / 3
Total51 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. First tube inserted cleanly in 12 rounds; the next two tubes were each dropped during large reorientation moves (grip at fingers 0.006-0.009 = shallow pinch).