Insert the Tubes · setup 7 · seed 40

B601-RS · gpt-6.1-sol · SAM 3 + grasp model · 28 rounds · 22 min thinking · 4.6 s motion

Goal not reachedProgress 10RoboDojo reward 0

“Insert the three tubes into the rack one by one.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_segmentgeometry_query

    Measure all three tubes and rack openings before selecting the first grasp.

    Next: Segment the tubes and back-project reference pixels.

  2. Round 1reach_mapgrasp_plangeometry_query

    The three tubes are separate on the table; start with the left tube.

    Next: Check low-target reachability, plan the left-tube grasp, and measure the rack rim.

  3. Round 2grasp_execute · completed

    The first tube has a reviewed, IK-admitted grasp proposal suitable for a lift attempt.

    Next: Execute candidate G0 for the leftmost tube.

  4. Round 3action_querymove_to · planner failedreach_map

    The first tube appears lifted; raise it further before reorienting.

    Next: Query the grasp result, raise the left gripper, and test upright orientations above the rack.

  5. Round 4move_toreach_map

    The first tube appears lifted, but its current grasp requires an awkward upward-facing gripper to turn the tip downward.

    Next: Raise the tube within the previously sampled reachable range and map upright orientations at nearby transfer positions.

  6. Round 5reach_mapreach_map

    The first tube followed the 6 cm lift and remains between the left jaws. None is inserted yet.

    Next: Map right-arm handoff orientations and higher left-arm upright poses.

  7. Round 6move_pose · not reached

    The first tube remains visibly retained after lift-off; no tube is inserted yet.

    Next: Move the left gripper to the high upright pose admitted by reach_map.

  8. Round 7recover_pose

    Recover the left arm before attempting further reorientation; no insertion is verified.

    Next: Return the left arm to its previous measured joint configuration while preserving closure.

  9. Round 8reach_mapreach_map

    The first tube remains visibly between the left jaws after recovery; no insertion is verified.

    Next: Check reachability before moving the held tube toward the right arm.

  10. Round 9move_to

    The first tube remains visibly retained; no tube is inserted.

    Next: Translate the left gripper to the central pose admitted by reach_map.

  11. Round 10reach_mapvision_segment

    The first tube followed the transfer and remains visibly between the left jaws; none is inserted yet.

    Next: Check right-arm reach at the cap and segment the exposed tube for grasp planning.

  12. Round 11reach_map

    The first tube remains visibly retained; no insertion is verified.

    Next: Check rotated transfer orientations before moving the tube.

  13. Round 12move_pose

    Reorient the retained tube at the central transfer position; no insertion is verified.

    Next: Move the left arm to the transfer orientation admitted by reach_map.

  14. Round 13reach_mapvision_segment

    The first tube followed the transfer and remains visibly retained; no insertion is verified.

    Next: Check right-arm reachability and segment the cap for handoff planning.

  15. Round 14grasp_planreach_map

    The first tube remains visibly retained; no insertion is verified.

    Next: Plan a cap grasp and check reachability at its measured height.

  16. Round 15reach_mapreach_map

    The first tube remains visibly retained; no insertion is verified.

    Next: Map upright tube orientations at two heights before commanding motion.

  17. Round 16reach_mapreach_map

    No insertion is verified. A different grip is needed for the sampled rack poses.

    Next: Map right-arm cap and approach poses before attempting a handoff.

  18. Round 17reach_mapreach_map

    No insertion is verified. A cap handoff remains the next feasible approach.

    Next: Map the current left-gripper orientation farther right at two heights.

  19. Round 18move_to

    The first tube remains visibly retained; no insertion is verified.

    Next: Move the left gripper to the mapped handoff region while preserving its grip.

  20. Round 19vision_segmentreach_map

    The first tube remains visibly retained; no insertion is verified.

    Next: Segment the exposed cap and check right-arm approach orientations.

  21. Round 20grasp_plan

    The first tube remains visibly retained; no insertion is verified.

    Next: Plan a right-arm cap grasp using the inspected current mask.

  22. Round 21move_pose

    The first tube remains visibly retained; no insertion is verified.

    Next: Move the right gripper to a cap pregrasp using the orientation previously admitted by reach_map.

  23. Round 22move_pose · not reached

    The first tube remains visibly retained; no insertion is verified.

    Next: Advance the right gripper toward the cap while preserving the left grip.

  24. Round 23reach_map

    No insertion is verified. The left gripper still visibly retains the first tube.

    Next: Check the alternate cap-grasp pose identified by the last planner result.

  25. Round 24move_pose · planner failed

    The first tube remains visibly held; no insertion is verified.

    Next: Approach the cap with the right-arm orientation admitted by reach_map in round 23.

  26. Round 25reach_map

    The first tube remains visibly held by the left gripper; no insertion is verified.

    Next: Map upright carrying poses before attempting further motion.

  27. Round 26reach_map

    The first tube is visibly retained; no tube insertion is verified.

    Next: Map upright poses at a lower height before commanding motion.

  28. Round 27move_pose · planner failed

    The left gripper visibly retains the first tube; no insertion is verified.

    Next: Try the alternate cap pose reported by the round-22 planner, using a precision approach.

Milestones

MilestonePoints
locate tubes & racklocate: head vision_segment + geometry_query identified the three tubes and the rack4 / 4
tubeA: grasp lift-off + followstubeA=tube2 (left): R2 grasp_execute rise 31mm, R4 lift +91mm, held to end (z 0.922, +144mm)6 / 6
tubeA: reorient upright (<~20deg)tube axis tilt stayed 84-90deg (horizontal) through R6 (stalled), R12 reorientation and R18; never uprighted0 / 6
tubeA: transport & align over rack holefinal tube2 (-0.010,-0.200) is ~210mm in front of the rack (0,0.011); not over rack (frame sol/s40_final_end_head.png)0 / 6
tubeA: insert into hole (depth>=45mm, upright)0 / 11
tubeA: release & retreat, stays upright0 / 3
tubeB: grasp lift-off + followstubeB/C never touched0 / 6
tubeB: reorient upright (<~20deg)0 / 6
tubeB: transport & align over rack hole0 / 6
tubeB: insert into hole (depth>=45mm, upright)0 / 11
tubeB: release & retreat, stays upright0 / 3
tubeC: grasp lift-off + follows0 / 6
tubeC: reorient upright (<~20deg)0 / 6
tubeC: transport & align over rack hole0 / 6
tubeC: insert into hole (depth>=45mm, upright)0 / 11
tubeC: release & retreat, stays upright0 / 3
Total10 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Held the first tube from R4 to the end but could never turn it upright with the side grasp; spent R13-R27 on right-arm cap-handoff planning whose approach moves IK-failed or hit inter-arm collision, ending on the call-time budget at 28 calls.