Organize the Table · setup 2 · seed 15

B601-RS · gpt-6.1-terra · SAM 3 + grasp model · 40 rounds · 40 min thinking · 12 s motion

Goal not reachedProgress 29RoboDojo reward 0

“Place the mouse on the mouse pad, push the keyboard into the frame, put the figurine on the stand, place the alarm clock on the drawer, then open the drawer and put all remaining miscellaneous items inside.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_groundgeometry_query

    Begin with the mouse placement using the right arm.

    Next: Ground the mouse and measure representative scene points.

  2. Round 1grasp_plangeometry_query

    Start with the mouse using the right arm.

    Next: Plan a mouse grasp and measure points on the pad.

  3. Round 2grasp_execute · completed

    The reviewed mouse grasp candidate is suitable for an initial attempt; its geometry and IK admission do not establish a grasp.

    Next: Execute the reviewed right-arm mouse candidate.

  4. Round 3geometry_querygeometry_querywait_ticks

    The mouse appears between the right fingers after the lift, but a secure grasp and lift-off are not yet established.

    Next: Measure visible mouse and pad points, then hold briefly and inspect the resulting observation.

  5. Round 4move_to · planner failed

    The right gripper is positioned around the mouse, but a grasp has not been verified.

    Next: Raise the right gripper approximately 6 cm while holding its orientation and gripper directive.

  6. Round 5move_to

    The mouse may be between the right gripper fingers, but a grasp and lift-off are not verified. A shorter upward motion was admitted by the preceding route sample.

    Next: Raise the right gripper approximately 3.5 cm while retaining its current orientation and grip directive.

  7. Round 6geometry_querygeometry_queryreach_map

    The mouse appears to have followed the right gripper during the short lift; its clearance and stability need measurement before transport.

    Next: Measure matching mouse points in the two wrist observations and map right-arm reach over the pad.

  8. Round 7geometry_query

    The mouse appears to have followed the right gripper during the lift, but stable retention is not yet established.

    Next: Measure points on the mouse pad in the current head view before planning placement.

  9. Round 8reach_map

    The mouse appears to have risen with the right gripper, but its retention is not yet confirmed stable.

    Next: Check right-arm reach above the pad before moving the mouse.

  10. Round 9move_to

    The mouse rose with the right gripper and appears retained, so a cautious transport toward the pad is warranted.

    Next: Move the right gripper above the mouse pad while preserving its current orientation and grip directive.

  11. Round 10geometry_query

    The mouse appears to be held above the mouse pad; placement has not yet been verified.

    Next: Back-project visible points on the pad and mouse using the current head image.

  12. Round 11geometry_queryreach_map

    The mouse appears to have followed the right gripper to the pad, but it has not been released or verified in place.

    Next: Query the current wrist depth and right-arm reach before lowering the mouse.

  13. Round 12geometry_querygeometry_query

    The mouse appears between the right fingers above the mouse pad, but its height above the pad and stability after release are not yet established.

    Next: Back-project visible pad and mouse pixels from observation obs-a7d9a12d1f4c47ca.

  14. Round 13move_pose

    The mouse appears to have followed the right gripper to the pad. A controlled lowering is warranted before release.

    Next: Lower the right gripper approximately 5.5 cm while preserving its orientation and grip.

  15. Round 14set_gripper

    The mouse appears positioned over the mouse pad and is ready for release.

    Next: Open the right gripper, then inspect the measured result and retreat.

  16. Round 15move_to · planner failed

    The mouse appears to rest on the mouse pad, but placement is not yet verified after retreat. The remaining tasks are unfinished.

    Next: Raise the open right gripper away from the mouse while holding its current orientation.

  17. Round 16move_to

    The mouse appears on the pad, but its stability after gripper retreat has not yet been verified.

    Next: Raise the right gripper to the previously sampled reachable height.

  18. Round 17geometry_query

    The mouse appears to rest on the mouse pad in obs-a68e262511fa4203. The keyboard remains in front of the outlined frame, so its push is the next task.

    Next: Measure visible keyboard and frame points from the current head RGB-D image.

  19. Round 18reach_map

    The mouse appears centered on the mouse pad. The keyboard is still in front of the outlined frame and needs to be pushed toward it.

    Next: Check the left arm’s kinematic reach near the keyboard before selecting a push pose.

  20. Round 19wait_ticksset_gripper

    The mouse appears centered on the pad after the gripper retreated. The keyboard remains in front of the outlined frame and is the next target.

    Next: Advance physics briefly and close the left gripper in preparation for a controlled keyboard push.

  21. Round 20reach_mapreach_map

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard remains in front of the outlined frame.

    Next: Check left-arm kinematic reach at the keyboard’s near edge and along the intended push path.

  22. Round 21move_pose

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard is the next target.

    Next: Move the closed left gripper above the keyboard’s near edge using an orientation admitted by the reach map.

  23. Round 22reach_mapgeometry_query

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard is still in front of the frame.

    Next: Check the left arm’s reach along the intended keyboard push path and measure visible keyboard-edge points.

  24. Round 23move_pose

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard remains outside the outlined frame.

    Next: Reorient the closed left gripper above the keyboard using the orientation admitted at the intended low contact point.

  25. Round 24move_to

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard remains in front of the frame; the left gripper is positioned for a cautious descent near its front edge.

    Next: Lower the closed left gripper near the keyboard’s front edge while holding its orientation.

  26. Round 25move_to

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard remains outside the outlined frame; the left gripper is near its front edge for an incremental push.

    Next: Move the closed left gripper approximately 4 cm toward the keyboard and inspect the result.

  27. Round 26move_to · planner failed

    The mouse appears to be on the pad. The keyboard’s final position is obscured by the left arm, so its placement is not yet verified.

    Next: Raise the left gripper clear of the keyboard, then inspect the resulting observation.

  28. Round 27move_to

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard’s placement remains obscured by the left arm.

    Next: Raise the left gripper by approximately 4 cm, within the preceding route’s sampled reachable portion.

  29. Round 28recover_pose

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard’s position relative to the frame remains obscured.

    Next: Return the left arm to its initial joint configuration to clear the view, then inspect the measured result and fresh imagery.

  30. Round 29geometry_queryreach_map

    The mouse appears stable on the pad after release, retreat, and a physics wait. The keyboard remains visibly in front of the outlined frame, so its placement is not complete.

    Next: Measure the keyboard and frame in the current head view and check left-arm reach along the prospective push path.

  31. Round 30move_pose

    The mouse appears stable on the pad. The keyboard remains in front of the outlined frame and needs another push.

    Next: Return the closed left gripper to the previously reached approach pose above the keyboard.

  32. Round 31move_pose

    The mouse appears stable on the pad. The keyboard remains in front of the outlined frame, and the remaining placements are unfinished.

    Next: Reorient the closed left gripper above the keyboard using the previously admitted low-contact orientation.

  33. Round 32move_to

    The mouse appears stable on the pad. The keyboard remains outside the outlined frame, and the other requested placements remain unfinished.

    Next: Lower the closed left gripper to the previously reached approach position near the keyboard edge.

  34. Round 33move_to

    The mouse appears stable on the pad. The keyboard remains outside the outlined frame, so another incremental push is warranted.

    Next: Move the closed left gripper toward the keyboard’s near edge.

  35. Round 34move_to

    The mouse appears stable on the pad after release, retreat and a physics wait. The keyboard still needs to be pushed into the frame.

    Next: Continue the closed left-gripper push toward the frame, then inspect the terminal result and fresh imagery.

  36. Round 35move_torecover_pose

    The mouse appears stable on the pad. The keyboard’s placement remains unverified, and the other requested tasks remain unfinished.

    Next: Raise the left gripper, then return the left arm home to clear the view.

  37. Round 36vision_groundgeometry_query

    The mouse appears stable on the mouse pad after release, retreat, and a physics wait. The keyboard remains visibly in front of the outlined frame, so its placement is unfinished.

    Next: Ground the figurine and measure the visible stand in the current head image.

  38. Round 37grasp_plan

    The mouse appears to be on the mouse pad. The figurine remains beside the outlined stand, and its pot is a plausible grasp target.

    Next: Plan a left-arm grasp on the visible pot.

  39. Round 38grasp_execute · completed

    The current candidate approaches the figurine’s base and is worth a grasp attempt, but retention and clearance are unverified.

    Next: Execute the first current figurine grasp candidate.

  40. Round 39wait_ticks

    The mouse appears stable on the mouse pad. The keyboard, figurine, clock, drawer, and miscellaneous-item tasks remain unfinished.

    Next: Hold the current commands for 10 control ticks, then inspect the resulting observation for figurine stability.

Milestones

MilestonePoints
mouse graspR2 rise 27mm, R5 +57mm, R9 carried 260mm8 / 8
mouse transportR9 held over pad7 / 7
mouse on mat (released, stays)R14 released; end frame mouse on pad [0.432,0.012]10 / 10
keyboard deliberate push toward frameR21-R34 left-arm push moves never contacted keyboard (0 mm); keyboard unmoved0 / 10
keyboard covers frame region0 / 15
figurine graspR38 grasp_execute rise 23mm, R39 hold 0.4s; run ended still holding, <1s follow4 / 8
figurine transport0 / 7
figurine upright on stand0 / 10
alarm grasp0 / 8
alarm transport0 / 7
alarm upright on drawer top0 / 10
open drawer & stow misc itemstask config spawns no miscellaneous items; reward has no drawer check; not scored0 / 0
Total29 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Keyboard push path planned at wrong height twice (two identical 5-move sequences, zero contact); figurine grasp only at the last round.