Plug In the Charger · setup 2 · seed 38

B601-RS · gpt-6.1-terra · SAM 3 + grasp model · 40 rounds · 21 min thinking · 8.5 s motion

Goal not reachedProgress 37.5RoboDojo reward 0

“Plug the charger into the power strip.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_groundgeometry_query

    The charger and power strip appear on the table in observation obs-fdc548655f9c4c46. Their positions and plug orientation need measurement before manipulation.

    Next: Measure points on the charger and strip and ground the charger for grasp planning.

  2. Round 1reach_mapgrasp_plan

    The small object is the charger; the longer object is the power strip. A left-arm grasp is the next step.

    Next: Query left-arm reach at the charger and generate grasp candidates.

  3. Round 2grasp_execute · completed

    The first candidate provides a reachable, oblique approach to the charger body with slightly more support clearance than the second candidate.

    Next: Execute the selected charger grasp candidate.

  4. Round 3move_pose · planner failed

    The charger appears between the left fingers after the probe lift, but retention is not yet established.

    Next: Raise the left gripper by 10 cm while holding its orientation and gripper command.

  5. Round 4move_pose

    A smaller lift is warranted to test whether the charger is held.

    Next: Raise the left gripper 0.05 m while holding its orientation and gripper directive.

  6. Round 5action_querygeometry_queryreach_mapwait_ticksobserve

    The charger appears to have lifted with the left gripper, but its stability and insertion alignment are not yet established.

    Next: Measure the strip, check left-arm reach, and hold the current pose briefly before observing again.

  7. Round 6geometry_querygeometry_query

    The charger appears retained between the left fingers after the lift and a short hold, but its exact pose and insertion alignment remain uncertain.

    Next: Measure visible charger and power-strip features from the current RGB-D observations.

  8. Round 7reach_map

    The charger appears to have followed the left gripper during the earlier lift and short hold. Its prongs appear roughly horizontal, so insertion requires reorientation and precise alignment.

    Next: Check reach near the strip with an approximate orientation that points the prongs downward.

  9. Round 8move_pose · planner failed

    The charger appears to have lifted and remained between the left fingers during a short hold. It still needs to be reoriented and aligned with a socket.

    Next: Raise the held charger to create clearance before moving toward the power strip.

  10. Round 9reach_mapgeometry_query

    The charger appears between the left fingers, but a grasp and lift-off have not been verified. The attempted 10 cm lift failed before motion because IK could not solve the requested pose.

    Next: Query the left arm’s reachable orientations near the intended lift height and measure points on the power strip.

  11. Round 10reach_map

    The charger appears to have followed the left gripper through the earlier 5 cm lift and short hold. Its retention during transport and its insertion alignment still need verification.

    Next: Check left-arm kinematic reach at an intermediate point toward the strip while retaining the current gripper orientation.

  12. Round 11move_pose

    The charger appears to have followed the left gripper during the 5 cm lift and short hold. An intermediate transport toward the strip is kinematically admitted, but retention during transport remains unverified.

    Next: Move the left gripper 10 cm toward the strip while holding its orientation and gripper command.

  13. Round 12geometry_querygeometry_query

    The charger appears held between the left fingers, but its prongs are not yet aligned with a socket. The task is not complete.

    Next: Measure visible charger and power-strip features in the current RGB-D views.

  14. Round 13geometry_queryreach_map

    The charger appears held between the left fingers, but insertion and retention are not yet verified. Its visible pins are not aligned for insertion into the upward-facing strip.

    Next: Measure visible pin and socket features and check low-height reachability before reorienting the charger.

  15. Round 14wait_ticks

    The charger appears to be held above the table, but stable retention and plug alignment remain unverified.

    Next: Hold the current commands briefly, then inspect a fresh observation.

  16. Round 15geometry_queryreach_map

    The charger appears to remain between the left fingers after transport and a short hold. Its pins are not yet aligned with the power strip, so the task is incomplete.

    Next: Measure the visible charger features and check the proposed reorientation at the current location and near the strip.

  17. Round 16reach_map

    The charger appears to remain between the left fingers after the transport and short hold, but its prongs are not aligned with the upward-facing strip. Insertion is incomplete.

    Next: Check the proposed reorientation at staging points before commanding it.

  18. Round 17reach_map

    The charger appears to remain between the left fingers after transport, but its prongs are not aligned with the strip and insertion is incomplete.

    Next: Check alternative yaw orientations for the proposed downward-prong pose at a staging height.

  19. Round 18reach_map

    The charger appears to remain between the left fingers after transport, but its prongs are not aligned with the power strip. Insertion is incomplete.

    Next: Check the proposed downward-prong orientations over a broader staging area.

  20. Round 19reach_map

    The charger appears to have followed the left gripper through the lift and transport, but its prongs are not aligned with the power strip. The task remains incomplete.

    Next: Check the proposed downward-prong orientations over staging points closer to the robot.

  21. Round 20reach_map

    The charger appears to have followed the left gripper during the lift and transport, but its prongs are not aligned with the strip; insertion is incomplete.

    Next: Check intermediate orientations at the current staging location before commanding a rotation.

  22. Round 21reach_map

    The charger appears to have followed the left gripper during lift and transport, but its pins are not aligned with the power strip. The task remains incomplete.

    Next: Check intermediate rotations at positions closer to the strip.

  23. Round 22move_pose

    The charger appears to have followed the left gripper through lift and transport, but its prongs are not aligned with the power strip. Insertion remains incomplete.

    Next: Move to the admitted intermediate orientation near the strip while preserving the gripper command.

  24. Round 23wait_ticks

    The charger appears to have followed the left gripper through the lift and transport, but it is not visibly plugged into the strip.

    Next: Hold the current commands for 10 control ticks, then inspect the resulting observation before further reorientation.

  25. Round 24geometry_queryreach_map

    The charger appears to remain between the left fingers, but its prongs are not visibly aligned with a socket and the task is incomplete.

    Next: Measure visible features and check intermediate orientations closer to the strip.

  26. Round 25move_pose

    The charger appears to have followed the left gripper during the lift and transport, but it is not plugged in. The reach map admits a further intermediate orientation above the strip.

    Next: Move the left gripper to the admitted intermediate pose while preserving its gripper command.

  27. Round 26action_querywait_ticks

    The charger appears to have followed the left gripper during the earlier lift and transport, but it is not visibly plugged into the power strip.

    Next: Query the last motion result and hold the current commands briefly to let the arm settle.

  28. Round 27move_pose · not reached

    The charger appears to remain between the left fingers after transport, but it is not visibly plugged into the strip.

    Next: Move to the previously admitted intermediate orientation at the nearby staging point while maintaining the gripper command.

  29. Round 28recover_pose

    The charger is beside the power strip with its prongs exposed; it is not visibly plugged in. The left arm should withdraw from its failed motion before another grasp is planned.

    Next: Recover the left arm to the joint configuration measured before the failed move, preserving its gripper command.

  30. Round 29vision_groundvision_ground

    The charger is not visibly plugged into the power strip. A new grasp may be needed after the failed reorientation.

    Next: Ground the charger in the current head and left-wrist images to assess its position before planning another grasp.

  31. Round 30reach_mapgrasp_plan

    The charger appears to be on the floor beneath the left wrist, so the previous recovery did not establish a grasp. I will check reachability and generate a current grasp proposal.

    Next: Query low-height reachability and plan a grasp from the current left-wrist target.

  32. Round 31grasp_execute · completed

    A current grasp candidate targets the charger body, but retention has not been established.

    Next: Execute the highest-clearance-height candidate through the grasp validation channel.

  33. Round 32geometry_queryvision_segment

    The charger is not yet plugged in, and the latest grasp attempt did not establish a lift.

    Next: Measure visible points on the charger and segment its body in the current left-wrist view.

  34. Round 33grasp_plan

    The charger appears to remain on the table after the attempted lift; a secure grasp is not established.

    Next: Generate current-observation grasp candidates for the segmented charger using the left arm.

  35. Round 34geometry_query

    The charger is not yet verified as grasped or plugged in. The current wrist image suggests it remains on the surface beside the power strip.

    Next: Measure visible points in the current left-wrist image to locate the charger and nearby strip.

  36. Round 35vision_segment

    The charger is not verified as grasped or plugged in. The current wrist image shows it below the fingers after the lift probe.

    Next: Segment the charger in the current left-wrist image.

  37. Round 36grasp_plan

    The charger is not verified as grasped or plugged in. A new grasp proposal is needed from its current position.

    Next: Plan a left-arm grasp on the charger mask in observation obs-97ed4de9a64a4b31.

  38. Round 37grasp_execute · completed

    The charger appears to remain on the surface after the previous lift probe; a retained grasp is not verified.

    Next: Execute the current lower-contact grasp candidate, then inspect the resulting observation.

  39. Round 38move_poseobserve

    The charger is not visibly plugged into the power strip. The preceding grasp attempt did not establish that it is held.

    Next: Raise the left gripper by 6 cm while retaining its current orientation and gripper command, then observe.

  40. Round 39finish_episode

    The charger is not plugged into the power strip; the task remains incomplete.

    Next: Stop the episode and declare the task incomplete.

Milestones

MilestonePoints
locate charger & socketlocate: head grounding/geometry (or scene_truth) identified charger and strip5 / 5
grasp: lift-off + follows gripperR2 rise 27mm, R4 lift +49mm (end +76mm), retained R11 transport20 / 20
reorient prongs down (local +y up) while heldR22/R25 intermediate orientations reached; never prongs-down7.5 / 15
transport held charger above socketR25 gripper at (-0.201,-0.107,0.903) above socket (-0.199,-0.122) but with wrong orientation5 / 10
align prongs over outlet & descend to contact0 / 15
insert: prongs inside socket (depth>=15mm, in footprint, upright)0 / 25
release & retreat, charger stays seated0 / 10
Total37.5 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Transported charger above the socket with an intermediate orientation, then a budget-exhausted reorientation dropped it and recovery knocked the strip; two regrasps failed.