Plug In the Charger · setup 2 · seed 41

B601-RS · gpt-6.1-terra · SAM 3 + grasp model · 40 rounds · 19 min thinking · 6.6 s motion

Goal not reachedProgress 30RoboDojo reward 0

“Plug the charger into the power strip.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_groundgeometry_query

    The charger and power strip are visible on the table; the left arm appears closest to the charger.

    Next: Ground the charger and measure points on the charger and power strip from the head camera.

  2. Round 1reach_mapgrasp_plan

    The small adapter in obs-05be25d8323d43bf is the charger; its visible prongs point roughly toward the near edge of the table. The left arm is the natural candidate for picking it up.

    Next: Query left-arm reach at the charger and generate grasp proposals for the visually inspected charger target.

  3. Round 2grasp_execute · completed

    The reviewed first candidate approaches the charger body and has a reachable pregrasp and contact pose in the planning-time IK check.

    Next: Execute the reviewed left-arm grasp candidate.

  4. Round 3geometry_querygeometry_query

    The charger appears between the left jaws after the lift, but a secure grasp and lift-off are not yet verified.

    Next: Measure visible charger and power-strip points in the current RGB-D views.

  5. Round 4move_posereach_map

    The charger appears between the left fingers after a short lift, but retention and lift-off are not yet verified.

    Next: Raise the left gripper while holding its orientation and closure, and check kinematic reach near the power strip.

  6. Round 5geometry_querygeometry_query

    The charger appears to have lifted with the left gripper, but insertion has not been attempted or verified.

    Next: Measure selected points in the current left-wrist RGB-D image.

  7. Round 6geometry_queryreach_map

    The charger appears lifted between the left fingers, but retention and stability are not yet verified. The visible prongs need to be aligned with a strip socket before insertion.

    Next: Query current RGB-D points and the left arm’s reach over the strip.

  8. Round 7geometry_querywait_ticksobserve

    The charger appears held between the left fingers after the lift, but retention and stability are not yet established.

    Next: Measure points on the strip, hold the current pose briefly, and acquire fresh views.

  9. Round 8geometry_queryreach_map

    The charger appears to have followed the left gripper during the lift and remains between the jaws after a short hold. Its prongs appear to point upward, so it needs reorientation before insertion.

    Next: Measure the charger in the current wrist view and check reach for the flipped gripper orientation above the strip.

  10. Round 9reach_mapreach_map

    The charger appears to have lifted and remained between the left fingers through a short hold. Its prongs appear to point roughly horizontally, so reorientation is needed before insertion.

    Next: Check the proposed 90-degree reorientation at several points above the strip.

  11. Round 10reach_map

    The charger appears to remain between the left jaws after the lift and short hold, but it is not plugged in. The tested orientation that would turn its prongs downward was not admitted at the sampled positions above the strip.

    Next: Check a wider set of positions for the required orientation before moving the held charger.

  12. Round 11reach_map

    The charger appears to have followed the left gripper during the lift and short hold, but it is not yet plugged in. The previously tested downward-prong orientation was not admitted at the tested positions.

    Next: Test three yaw variants of the proposed downward-prong orientation over a small grid above the strip.

  13. Round 12vision_groundreach_map

    The charger appears to have followed the left gripper during the lift and remained between its jaws during a short hold. It is not yet plugged in. The tested left-arm orientations for turning the prongs downward were not admitted near the strip.

    Next: Ground the held charger in the current wrist view and check right-arm reach near it as a possible handoff.

  14. Round 13reach_mapreach_map

    The charger appears to have followed the left gripper during the lift and remained between its jaws during a short hold. It is not yet plugged in. A handoff may make the required reorientation possible.

    Next: Check both arms’ kinematic reach in a region closer to the right arm, including the left gripper’s current orientation.

  15. Round 14move_pose

    The charger followed the left gripper during the lift and a short hold, but it is not plugged in. A shared reachable region may permit a handoff.

    Next: Move the left gripper toward the shared reachable region while preserving its orientation and closure.

  16. Round 15geometry_querygeometry_query

    The charger appears to be held above the power strip, but insertion has not been verified.

    Next: Measure visible points in the current wrist image.

  17. Round 16wait_ticks

    The charger appears held above the power strip, but its prongs are not yet aligned for insertion. Stability must be checked before repositioning.

    Next: Hold the current commands for 10 control ticks, then inspect the measured result and fresh camera views.

  18. Round 17geometry_queryreach_map

    The charger has followed the left gripper through the lift and transport and remains between its jaws after the latest hold. It is not yet plugged in.

    Next: Measure the visible charger and prong points and test the previously proposed reorientation near the current gripper position.

  19. Round 18vision_segment

    The charger followed the left gripper during lift and transport and remains between its jaws after the hold, but it is not plugged in. A right-arm regrasp may allow the prongs to be turned downward.

    Next: Segment the visible charger in the current left-wrist image and inspect the resulting previews before requesting grasp candidates.

  20. Round 19grasp_plangeometry_query

    The charger followed the left gripper during lift and transport and remained between its jaws during a short hold. It is not yet plugged in; a right-arm handoff may enable the required reorientation.

    Next: Generate right-arm grasp proposals for the segmented charger and measure visible points on the power strip.

  21. Round 20reach_map

    The charger remains held by the left gripper, but is not plugged in. A wider reachability search may identify a place to turn its prongs downward without a handoff.

    Next: Test the previously derived downward-prong orientations over a wider, higher grid for the left arm.

  22. Round 21reach_mapgeometry_query

    The charger has followed the left gripper through a lift and transport, but it is not plugged in. The tested orientations for turning its prongs downward were not admitted near the strip, and the right-arm grasp proposals were unreachable.

    Next: Check the left arm’s current orientation at lower heights near its present position before planning a controlled set-down and regrasp.

  23. Round 22move_pose

    The charger followed the left gripper during the earlier lift and transport, but it is not plugged in. A controlled set-down may allow a different grasp for reorientation.

    Next: Lower the left gripper 5 cm while preserving its orientation and closure, then inspect the measured result and fresh views.

  24. Round 23geometry_querywait_ticks

    The charger has followed the left gripper through the earlier lift and transport, but it is not plugged in. It may now be close to a supporting surface for a regrasp.

    Next: Measure visible charger and strip points, then let the current pose settle.

  25. Round 24move_pose

    The charger has followed the left gripper through lifting and transport, but it is not plugged in. Lowering it toward the table may enable a regrasp with a more useful orientation.

    Next: Lower the left gripper 3.5 cm while preserving its orientation and closure, then inspect the measured result and fresh views.

  26. Round 25geometry_query

    The charger remains between the left jaws, but it is not plugged in. The current lowering move was intended to prepare for a supported set-down and regrasp.

    Next: Measure selected charger and power-strip points in the current left-wrist view.

  27. Round 26action_querymove_pose

    The charger remains between the left jaws but is not aligned with a socket. A controlled set-down may allow a more useful regrasp.

    Next: Lower the left gripper another 1.5 cm while preserving its orientation and closure, then inspect the terminal result and fresh views.

  28. Round 27wait_ticks

    The charger is not plugged in. It remains between the left jaws near the power strip, and a supported set-down may permit a more useful regrasp.

    Next: Hold the current commands briefly and inspect the resulting observation.

  29. Round 28set_gripper

    The charger is not plugged in. It remains between the left jaws near the power strip and appears close to a supporting surface for a regrasp.

    Next: Open the left gripper to begin releasing the charger onto the nearby surface.

  30. Round 29wait_ticks

    The charger has been released beside the power strip but is not visibly plugged in. A new grasp may permit a better insertion orientation.

    Next: Hold the current commands for 10 ticks and inspect the resulting observation before planning a regrasp.

  31. Round 30vision_groundgeometry_query

    The charger is lying beside the power strip and is not visibly plugged in. A new grasp must be established before insertion.

    Next: Ground the charger in the left wrist view and measure points on the charger and nearby socket.

  32. Round 31grasp_plan

    The charger is visible beside the power strip, but it has not been grasped or plugged in.

    Next: Plan a grasp on the charger using its current left-wrist segmentation.

  33. Round 32grasp_execute · completed

    The charger remains beside the power strip and is not visibly plugged in. The reviewed grasp candidate is suitable for an attempt, but its success is unproven.

    Next: Execute the reviewed left-arm grasp candidate with the highest proposed contact height.

  34. Round 33move_pose

    The charger appears between the left jaws, but a stable grasp and lift-off are not yet verified.

    Next: Raise the left gripper 6 cm while preserving its orientation and gripper command.

  35. Round 34geometry_querywait_ticks

    The charger appears to have lifted with the left gripper, but insertion has not been attempted or verified. Its current orientation and stability need measurement before alignment.

    Next: Measure visible points in the left-wrist image and hold the current commands briefly.

  36. Round 35geometry_queryreach_map

    The charger appears to have followed the left gripper during lift, but it is not visibly plugged in. A new reorientation estimate needs a reachability check before any insertion attempt.

    Next: Measure the visible charger and socket features and test candidate downward-prong orientations near the strip.

  37. Round 36reach_mapreach_map

    The charger appears to have lifted with the left gripper and remained between the jaws during the last hold, but it is not plugged in. The tested downward-prong orientations were not admitted near the strip at the sampled height.

    Next: Check the estimated insertion orientations over the current grasp area and above the power strip at a higher fingertip height.

  38. Round 37move_pose

    The charger appears to be held above the strip, but it is not plugged in. The tested insertion orientations were not admitted at the sampled positions, so I will return it toward its previous supported position.

    Next: Lower the left gripper 6 cm along its recent lift path while preserving its orientation and closure.

  39. Round 38set_gripper

    The charger is beside the power strip and is not visibly plugged in. The last lowering movement brought it close to the supporting surface, so release it there.

    Next: Open the left gripper to release the charger.

  40. Round 39move_pose

    The charger is beside the power strip and is not visibly plugged in. The attempted grasp was returned to the surface because the sampled insertion orientations were not admitted by the reachability checks.

    Next: Retreat the open left gripper upward along the recent lift path.

Milestones

MilestonePoints
locate charger & socketlocate: head grounding/geometry (or scene_truth) identified charger and strip5 / 5
grasp: lift-off + follows gripperR2 rise 29mm, R4 lift +80mm (end +110mm), held R14 transport +231mm20 / 20
reorient prongs down (local +y up) while heldno rotation ever executed (all pins-down reach_maps rejected)0 / 15
transport held charger above socketR14 charger held over strip end at x=-0.16 (socket centre -0.261) but not oriented5 / 10
align prongs over outlet & descend to contact0 / 15
insert: prongs inside socket (depth>=15mm, in footprint, upright)0 / 25
release & retreat, charger stays seated0 / 10
Total30 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Never found a reachable prongs-down pose; set the charger down, regrasped identically, and set it down again.