Push the T · setup 1 · seed 36
B601-RS · gpt-6-astra · SAM 3 + grasp model · 40 rounds · 36 min thinking · 7.8 s motion
“Push the T-shaped block to align it precisely with the gray T-shaped pad.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0move_pose · planner failedset_gripperset_gripperset_gripperset_gripperset_gripper
Plan a left-arm push from the block’s left side, with a slight offset to encourage clockwise rotation.
Next: Move above the push starting point and close the left gripper incrementally.
Round 1align_plan
The block needs approximately 18 cm of rightward translation plus an orientation correction. A reachable pushing pose must be established first.
Next: Request read-only IK candidates above the block.
Round 2move_pose · planner failed
Try an inclined approach above the block’s left side before contact.
Next: Move the left gripper above the proposed push starting point.
Round 3move_pose
Move to the intermediate pose that passed the controller’s sampled IK check before attempting further descent.
Next: Move the closed left gripper to the sampled intermediate pose above the table.
Round 4move_pose · planner failed
Continue positioning for a controlled push; alignment is incomplete.
Next: Lower the closed left gripper behind the block to a staging height.
Round 5move_pose
Use the controller’s reachable orientation estimate to approach behind the block.
Next: Move the closed left gripper to the suggested reachable approach pose.
Round 6move_pose · planner failed
Lower the closed left fingertips behind the block before pushing.
Next: Descend to z=0.774 m behind the block, preserving the inclined orientation.
Round 7move_pose
Use the intermediate pose admitted by the previous reachability diagnostic before attempting contact.
Next: Lower the closed left gripper to the diagnostic intermediate pose.
Round 8move_pose · planner failed
The block remains separated from the pad; approach its left edge before pushing.
Next: Move the closed left gripper slightly right and down to the block’s side.
Round 9move_pose
Use the shorter approach admitted by the controller’s IK diagnostic.
Next: Move the left gripper to the reachable intermediate pose, preserving its orientation and closed fingers.
Round 10move_pose
Ready for a short push toward the pad; alignment remains incomplete.
Next: Move the closed left gripper about 35 mm toward +world X at the block’s side.
Round 11move_pose
Continue a short push toward the pad; alignment remains incomplete.
Next: Push toward +world X while holding orientation and contact height.
Round 12move_pose
The block moved toward the pad; further pushing is required.
Next: Push toward +X while shifting contact slightly toward the block’s centerline.
Round 13move_pose · planner failed
The block moved toward the pad but needs a rotation correction.
Next: Reposition the closed left fingertips beside the block’s lower side before a corrective push.
Round 14move_pose
Alignment remains incomplete; use an intermediate repositioning target supported by the controller’s IK diagnostic.
Next: Move the closed left fingertips 26 mm toward the intermediate withdrawal position.
Round 15move_pose · planner failed
The block still needs translation and angular correction.
Next: Make a short diagonal push against the lower side to advance the block and encourage counterclockwise rotation.
Round 16wait_ticks
Alignment remains incomplete. Let the previous reposition settle before another push.
Next: Advance eight control ticks (0.32 simulated seconds), holding current commands.
Round 17move_pose · not reached
The block remains separated from the pad. A short corrective push is appropriate.
Next: Push toward +X at the current Y, aiming to translate the block and correct its rotation.
Round 18move_pose · not reached
Alignment remains incomplete. Continue the current short push before extending it.
Next: Repeat the previous endpoint and orientation to allow further progress.
Round 19move_pose
The block is moving toward the pad but remains substantially misaligned.
Next: Push approximately 37 mm toward +world X, holding the current gripper orientation.
Round 20move_pose · planner failed
The block advanced toward the pad, but angular alignment worsened. Reposition for a corrective push.
Next: Move the left pusher toward the stem side while maintaining height and orientation.
Round 21move_pose
Alignment remains incomplete. Try the shorter reposition admitted by the IK diagnostic.
Next: Move the left pusher 17.75 mm toward negative world Y, preserving orientation and closed fingers.
Round 22move_pose · planner failed
Alignment remains incomplete; reposition toward the lower stem for a corrective push.
Next: Move the closed left gripper toward [-0.140, -0.295, 0.776] m, holding orientation.
Round 23move_pose
Alignment remains incomplete. Use the shorter approach admitted by the IK diagnostic.
Next: Move the closed left gripper to the reachable intermediate position below the block’s stem.
Round 24move_pose
Alignment remains incomplete; push near the stem tip to correct rotation.
Next: Move the closed left gripper toward +X at the lower stem.
Round 25move_pose
Alignment remains incomplete; continue a short push near the stem tip to correct rotation.
Next: Push the left gripper toward world +X while maintaining its height and orientation.
Round 26move_pose · planner failed
Rotation improved; precise alignment remains unverified.
Next: Raise the left pusher vertically before measuring the remaining correction.
Round 27move_pose
Withdraw using the diagnostic’s reachable orientation, then measure alignment.
Next: Move the left pusher upward with the reported reachable quaternion.
Round 28move_pose · planner failed
Alignment remains incomplete; prepare a short corrective push.
Next: Move above the stem’s lower-left side, restoring the previously used pushing orientation.
Round 29move_pose
Alignment remains incomplete. Use the controller’s nearby reachable orientation to approach for correction.
Next: Move the closed left gripper above the stem using the suggested reachable pose.
Round 30move_pose · planner failed
The block remains offset from the pad; precise alignment is not established.
Next: Lower the closed left gripper beside the stem before a short corrective push.
Round 31move_pose
Alignment remains incomplete. Use the nearby orientation that passed the endpoint IK query to approach the block.
Next: Lower the closed left gripper beside the block using the returned reachable orientation.
Round 32move_pose · not reached
The block remains offset; a short diagonal push is appropriate.
Next: Move the closed left pusher diagonally toward the pad while lowering to side-contact height.
Round 33move_pose · not reached
Precise alignment is not achieved; attempt a short horizontal correction.
Next: Move the closed left pusher toward +X,+Y while holding its current height and orientation.
Round 34move_pose · not reached
Alignment remains incomplete. Try a revised pusher orientation at the same short-push endpoint.
Next: Command the left pusher toward [-0.090,-0.255,0.7783] m with the earlier effective push orientation.
Round 35move_pose
Precise alignment remains unachieved; try a slightly higher corrective push.
Next: Move the left pusher diagonally toward the pad, raising the requested height by 4 mm while holding orientation.
Round 36wait_ticks
The block moved toward the pad; precise alignment remains unverified.
Next: Advance eight ticks to let the current command settle, then remeasure.
Round 37move_pose
The block overshot the pad; precise alignment has not been achieved.
Next: Withdraw the left pusher above the table, then remeasure and check stability.
Round 38wait_ticks
Precise alignment has not been achieved.
Next: Advance physics eight ticks with the pusher withdrawn, then inspect the block.
Round 39finish_episode
Precise alignment was not achieved.
Next: End the episode as unsuccessful at the round limit.
Milestones
| Milestone | Points |
|---|---|
| approach & contact T, first error-reducing pushfirst improving push round 10; T touched in 14 actions | 10 / 10 |
| coarse transport: final pos error <=50% of initial (177mm)final pos err 28mm (16% of initial) | 15 / 15 |
| position within 30mm of pad (0.5 if <=60mm)final 28.2mm | 20 / 20 |
| position within 7mm (task threshold; 0.5 if <=15mm)final 28.2mm | 0 / 20 |
| yaw within 15deg while pos<=60mm (0.5 if <=30deg)final yaw err 27.4deg (initial 15.0) | 7.5 / 15 |
| yaw within 7deg while pos<=30mm (0.5 if <=12deg)final yaw err 27.4deg | 0 / 15 |
| T flat & stationary at end with arm retreated (only if pos<=60mm)final tilt 0.0deg, last T-moving action round 36, last physical action round 38 | 5 / 5 |
| Total | 57.5 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Reached 8mm/-1deg at r35, then a wait_ticks with the pusher still in contact (r36) let T spring to 28mm/27deg; final correction attempts r37-38 did not recover; 17 IK/stall failures.