Store the Laptop and Headphones · setup 1 · seed 36

B601-RS · gpt-6-astra · SAM 3 + grasp model · 40 rounds · 27 min thinking · 9.7 s motion

Goal not reachedProgress 9RoboDojo reward 0

“Hang the headphones on the headphone stand, close the laptop, then place it into the vertical laptop stand.”

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of motion. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them. Names such as scene_truth are the tools it could call.

  1. Round 0vision_groundgeometry_query

    Locate a headphone grasp and measure the stand before moving.

    Next: Ground the headphones and measure visible support points.

  2. Round 1grasp_plan

    The inspected T0 preview matches the headphones; request grasp proposals before moving.

    Next: Plan a left-arm headphone grasp.

  3. Round 2grasp_planalign_plan

    Check alternative arm and approach geometry before moving.

    Next: Request right-arm grasp proposals and a read-only headband alignment plan.

  4. Round 3align_planalign_plan

    Check a right-arm approach above the headband before attempting contact.

    Next: Request read-only alignment plans 10 cm and 20 cm above the visible headband.

  5. Round 4vision_groundgeometry_query

    Locate a reachable headphone grasp before moving either arm.

    Next: Ground the headphones and measure visible placement references.

  6. Round 5vision_segmentalign_plan

    Locate a graspable section of the headphone headband before moving.

    Next: Segment the headphones and request left-arm alignment above the headband.

  7. Round 6move_pose · planner failed

    Try an elevated, tilted approach before attempting headphone contact.

    Next: Move the right gripper above the headphones with a tilted downward approach.

  8. Round 7move_pose

    Use the alternative elevated pose identified by the IK diagnostic before approaching the headphones.

    Next: Move the right arm to the diagnostic's reachable endpoint with its tilted orientation.

  9. Round 8move_pose · planner failed

    Approach the right headphone earcup in stages using the attained tilted orientation.

    Next: Move the open right gripper above and in front of the right earcup.

  10. Round 9move_pose · planner failed

    Try an intermediate pose derived from the robot design and measured joints.

    Next: Move the open right gripper toward an elevated headband approach.

  11. Round 10move_pose

    Use the controller-reported reachable orientation for the next elevated approach.

    Next: Move the open right gripper to the revised intermediate pose.

  12. Round 11move_pose

    Continue the staged approach with the right gripper open.

    Next: Lower the right gripper to an estimated approach pose above the headband.

  13. Round 12move_pose · planner failed

    Continue the open-gripper approach toward the headphone band.

    Next: Lower the right gripper to z=0.80 m while holding its orientation.

  14. Round 13move_pose

    Try the alternative orientation identified by the controller diagnostic for the headphone approach.

    Next: Move the open right gripper to the revised approach pose.

  15. Round 14set_gripper

    Attempt incremental closure at the current headphone approach pose.

    Next: Close the right gripper while holding its pose.

  16. Round 15move_pose

    Grasp remains unverified; perform a small vertical lift test.

    Next: Raise the right gripper 6 cm while preserving orientation and closure.

  17. Round 16set_grippervision_ground

    The lift test did not establish a grasp; visible headphone surfaces remained stationary.

    Next: Open the right gripper and locate the headphones again.

  18. Round 17move_pose

    Retract the open right gripper to expose the headphone band for a revised grasp.

    Next: Return to the previously reached elevated approach pose.

  19. Round 18move_pose · planner failed

    Revise the grasp to the right side of the headband, where the current jaw direction crosses the band.

    Next: Move the open right gripper toward the measured side-band location.

  20. Round 19move_pose · not reached

    Try the revised orientation identified by the controller diagnostic for the side-band approach.

    Next: Move the open right gripper to the diagnostic's alternative pose.

  21. Round 20set_gripper

    Attempt closure at the measured pose without pushing farther into the stalled approach.

    Next: Close the right gripper while holding its current pose.

  22. Round 21move_pose

    Grasp remains unverified; perform a small lift test.

    Next: Raise the right gripper 6 cm while preserving orientation and closure.

  23. Round 22set_grippermove_pose

    The second lift did not establish a grasp; reposition before another attempt.

    Next: Open the right gripper and retract to the previously reached elevated pose.

  24. Round 23move_pose · not reached

    Try a revised approach to the right earcup.

    Next: Move the open right gripper to the estimated earcup grasp pose.

  25. Round 24move_pose · not reached

    Try the nearby orientation identified by the IK diagnostic for the earcup approach.

    Next: Move the open right gripper to the diagnostic’s alternative pose.

  26. Round 25set_gripper · not reached

    Attempt closure at the measured pose without driving farther into the stalled approach.

    Next: Close the right gripper while holding its current pose.

  27. Round 26move_to · planner failed

    A small lift test is warranted; grasp remains unverified.

    Next: Raise the right gripper 6 cm while preserving orientation and finger drive.

  28. Round 27move_pose

    Attempt the lift with the reported reachable orientation; grasp remains unverified.

    Next: Raise the right gripper approximately 6 cm with the IK-suggested 15-degree orientation adjustment, preserving finger drive.

  29. Round 28wait_ticks

    The headphones appear lifted, but stable retention still needs verification before transport.

    Next: Hold the current commands for eight control ticks.

  30. Round 29move_pose

    Observed lift-off and stability support a staged transfer toward the headphone stand.

    Next: Raise and move the right gripper leftward while turning the headphones 45 degrees toward vertical.

  31. Round 30vision_ground

    Pause the transfer to verify headphone retention.

    Next: Ground the headphones in the current head image and inspect the returned previews.

  32. Round 31recover_pose · not reachedobserve

    The grounding results do not reliably identify the headphones; clear the arm occlusion before continuing.

    Next: Return the right arm home while preserving its gripper directive, then inspect fresh views.

  33. Round 32vision_groundalign_plan

    The headphones slipped during transfer; a new grasp is needed at their current location.

    Next: Locate the headphones and check a left-arm approach above the visible headband.

  34. Round 33grasp_plan

    A new headphone grasp is needed; no task placement is complete.

    Next: Generate grasp candidates for the visually inspected headphone mask.

  35. Round 34grasp_planalign_plan

    The current left-arm grasp candidates cannot be executed; check alternative reachability.

    Next: Plan right-arm grasps and check a left-arm approach above the visible earcup.

  36. Round 35move_pose · planner failed

    Try an elevated left-arm approach derived from robot geometry and measured joints.

    Next: Move the open left gripper above the visible earcup.

  37. Round 36move_pose

    Use the controller-reported reachable alternative for the elevated left-arm approach.

    Next: Move the open left gripper above the earcup with the suggested orientation.

  38. Round 37vision_ground

    The left arm is positioned for further grasp planning; no grasp or placement is established.

    Next: Ground the headphones in the current left-wrist image.

  39. Round 38action_querygrasp_plan

    The headphone mask matches the visible object; request grasp candidates for inspection.

    Next: Query the previous motion result and plan a left-arm headphone grasp.

  40. Round 39finish_episode

    Task incomplete; stopping at the run’s round limit.

    Next: Record an incomplete outcome without further manipulation.

Milestones

MilestonePoints
headset: approach (gripper reached pregrasp/contact pose)R7 move_pose reached elevated pregrasp3 / 3
headset: grasp & lift (>=30 mm, stays elevated through a hold and a following motion)R25 right close stalled 0.029, R27 lift r68 z+75, R28 hold z+80; lost on first transport R29 (z->0)6 / 12
headset: carried to the stand (held, elevated, within ~100 mm of cradle)R29 transport ended with headset back on the table (d279, end z 0)0 / 8
headset: hung on cradle, released, stable after retreatnot hung0 / 12
laptop: lid closed (>=85% hinge)laptop never closed (no lid-closing contact achieved; laptop base unmoved or only displaced)0 / 20
laptop: closed laptop grasped & liftedlaptop not grasped/lifted0 / 15
laptop: carried to vertical rackn/a0 / 10
laptop: inserted upright in rack, released, stablen/a0 / 20
Total9 / 100

Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.

Key failure. Right-arm earcup grasp held only statically; first transport toward the stand dropped it, then 10 rounds of left-arm re-planning without contact.