Store the Laptop and Headphones · setup 1 · seed 36
B601-RS · gpt-6-astra · SAM 3 + grasp model · 40 rounds · 27 min thinking · 9.7 s motion
“Hang the headphones on the headphone stand, close the laptop, then place it into the vertical laptop stand.”
- Moved an object
- Moved the arm only
- Failed or stopped
- Width = seconds of motion. Select a segment to jump to it.
Model Report, Round by Round
As the model wrote them. Names such as scene_truth are the tools it could call.
Round 0vision_groundgeometry_query
Locate a headphone grasp and measure the stand before moving.
Next: Ground the headphones and measure visible support points.
Round 1grasp_plan
The inspected T0 preview matches the headphones; request grasp proposals before moving.
Next: Plan a left-arm headphone grasp.
Round 2grasp_planalign_plan
Check alternative arm and approach geometry before moving.
Next: Request right-arm grasp proposals and a read-only headband alignment plan.
Round 3align_planalign_plan
Check a right-arm approach above the headband before attempting contact.
Next: Request read-only alignment plans 10 cm and 20 cm above the visible headband.
Round 4vision_groundgeometry_query
Locate a reachable headphone grasp before moving either arm.
Next: Ground the headphones and measure visible placement references.
Round 5vision_segmentalign_plan
Locate a graspable section of the headphone headband before moving.
Next: Segment the headphones and request left-arm alignment above the headband.
Round 6move_pose · planner failed
Try an elevated, tilted approach before attempting headphone contact.
Next: Move the right gripper above the headphones with a tilted downward approach.
Round 7move_pose
Use the alternative elevated pose identified by the IK diagnostic before approaching the headphones.
Next: Move the right arm to the diagnostic's reachable endpoint with its tilted orientation.
Round 8move_pose · planner failed
Approach the right headphone earcup in stages using the attained tilted orientation.
Next: Move the open right gripper above and in front of the right earcup.
Round 9move_pose · planner failed
Try an intermediate pose derived from the robot design and measured joints.
Next: Move the open right gripper toward an elevated headband approach.
Round 10move_pose
Use the controller-reported reachable orientation for the next elevated approach.
Next: Move the open right gripper to the revised intermediate pose.
Round 11move_pose
Continue the staged approach with the right gripper open.
Next: Lower the right gripper to an estimated approach pose above the headband.
Round 12move_pose · planner failed
Continue the open-gripper approach toward the headphone band.
Next: Lower the right gripper to z=0.80 m while holding its orientation.
Round 13move_pose
Try the alternative orientation identified by the controller diagnostic for the headphone approach.
Next: Move the open right gripper to the revised approach pose.
Round 14set_gripper
Attempt incremental closure at the current headphone approach pose.
Next: Close the right gripper while holding its pose.
Round 15move_pose
Grasp remains unverified; perform a small vertical lift test.
Next: Raise the right gripper 6 cm while preserving orientation and closure.
Round 16set_grippervision_ground
The lift test did not establish a grasp; visible headphone surfaces remained stationary.
Next: Open the right gripper and locate the headphones again.
Round 17move_pose
Retract the open right gripper to expose the headphone band for a revised grasp.
Next: Return to the previously reached elevated approach pose.
Round 18move_pose · planner failed
Revise the grasp to the right side of the headband, where the current jaw direction crosses the band.
Next: Move the open right gripper toward the measured side-band location.
Round 19move_pose · not reached
Try the revised orientation identified by the controller diagnostic for the side-band approach.
Next: Move the open right gripper to the diagnostic's alternative pose.
Round 20set_gripper
Attempt closure at the measured pose without pushing farther into the stalled approach.
Next: Close the right gripper while holding its current pose.
Round 21move_pose
Grasp remains unverified; perform a small lift test.
Next: Raise the right gripper 6 cm while preserving orientation and closure.
Round 22set_grippermove_pose
The second lift did not establish a grasp; reposition before another attempt.
Next: Open the right gripper and retract to the previously reached elevated pose.
Round 23move_pose · not reached
Try a revised approach to the right earcup.
Next: Move the open right gripper to the estimated earcup grasp pose.
Round 24move_pose · not reached
Try the nearby orientation identified by the IK diagnostic for the earcup approach.
Next: Move the open right gripper to the diagnostic’s alternative pose.
Round 25set_gripper · not reached
Attempt closure at the measured pose without driving farther into the stalled approach.
Next: Close the right gripper while holding its current pose.
Round 26move_to · planner failed
A small lift test is warranted; grasp remains unverified.
Next: Raise the right gripper 6 cm while preserving orientation and finger drive.
Round 27move_pose
Attempt the lift with the reported reachable orientation; grasp remains unverified.
Next: Raise the right gripper approximately 6 cm with the IK-suggested 15-degree orientation adjustment, preserving finger drive.
Round 28wait_ticks
The headphones appear lifted, but stable retention still needs verification before transport.
Next: Hold the current commands for eight control ticks.
Round 29move_pose
Observed lift-off and stability support a staged transfer toward the headphone stand.
Next: Raise and move the right gripper leftward while turning the headphones 45 degrees toward vertical.
Round 30vision_ground
Pause the transfer to verify headphone retention.
Next: Ground the headphones in the current head image and inspect the returned previews.
Round 31recover_pose · not reachedobserve
The grounding results do not reliably identify the headphones; clear the arm occlusion before continuing.
Next: Return the right arm home while preserving its gripper directive, then inspect fresh views.
Round 32vision_groundalign_plan
The headphones slipped during transfer; a new grasp is needed at their current location.
Next: Locate the headphones and check a left-arm approach above the visible headband.
Round 33grasp_plan
A new headphone grasp is needed; no task placement is complete.
Next: Generate grasp candidates for the visually inspected headphone mask.
Round 34grasp_planalign_plan
The current left-arm grasp candidates cannot be executed; check alternative reachability.
Next: Plan right-arm grasps and check a left-arm approach above the visible earcup.
Round 35move_pose · planner failed
Try an elevated left-arm approach derived from robot geometry and measured joints.
Next: Move the open left gripper above the visible earcup.
Round 36move_pose
Use the controller-reported reachable alternative for the elevated left-arm approach.
Next: Move the open left gripper above the earcup with the suggested orientation.
Round 37vision_ground
The left arm is positioned for further grasp planning; no grasp or placement is established.
Next: Ground the headphones in the current left-wrist image.
Round 38action_querygrasp_plan
The headphone mask matches the visible object; request grasp candidates for inspection.
Next: Query the previous motion result and plan a left-arm headphone grasp.
Round 39finish_episode
Task incomplete; stopping at the run’s round limit.
Next: Record an incomplete outcome without further manipulation.
Milestones
| Milestone | Points |
|---|---|
| headset: approach (gripper reached pregrasp/contact pose)R7 move_pose reached elevated pregrasp | 3 / 3 |
| headset: grasp & lift (>=30 mm, stays elevated through a hold and a following motion)R25 right close stalled 0.029, R27 lift r68 z+75, R28 hold z+80; lost on first transport R29 (z->0) | 6 / 12 |
| headset: carried to the stand (held, elevated, within ~100 mm of cradle)R29 transport ended with headset back on the table (d279, end z 0) | 0 / 8 |
| headset: hung on cradle, released, stable after retreatnot hung | 0 / 12 |
| laptop: lid closed (>=85% hinge)laptop never closed (no lid-closing contact achieved; laptop base unmoved or only displaced) | 0 / 20 |
| laptop: closed laptop grasped & liftedlaptop not grasped/lifted | 0 / 15 |
| laptop: carried to vertical rackn/a | 0 / 10 |
| laptop: inserted upright in rack, released, stablen/a | 0 / 20 |
| Total | 9 / 100 |
Scored from the simulator’s physics record by AI reviewer agents following one rubric; not yet checked by a person.
Key failure. Right-arm earcup grasp held only statically; first transport toward the stand dropped it, then 10 rounds of left-arm re-planning without contact.