Coin bank · layout 33 · gpt-6.2-astra · open coordinates

B601 · Zoetic harness 0.4.51 · 8 rounds · 13 requests · 0.71M input tokens · 5 min model time · 12 min wall clock

Met except arms homeRoboDojo graded score 20Not within RoboDojo’s step limitModel declared the task finishedCPU physics

“Pick up the coin from the holder and insert it precisely into the coin bank.”

The task. Take a coin from its holder and push it through the slot of a coin bank. The slot is narrow and the coin has to go in edge first.

What the model had. Everything in sensor-only mode, plus a tool, scene_read, that asks the simulator for each object’s position, orientation and size (simulation only). Its opening note asked it to consider spatial information first and to report which values it used. It called scene_read 24 times, 23 of them inside its own programs.

Host’s offline check. Met without the arms-home condition; the original reading still requires the arms home at the end. The task run ended at control step 570; RoboDojo’s limit for this task is 300. The model never saw this check.

The last two rounds. The model held off releasing because of the coin’s tilt, re-centred, then let go. Two position reads before and after the arm left agreed, and it reported the coin centre 97.7 mm below the slot.

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of simulated motion. “Moved” means an object shifted at least 5 mm. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them: its judgment, its target for the round, its check of the previous step, and its next step. Names such as place_and_release, scene_read and run_program are harness tools it could call; tools indented under run_program ran inside one of its programs. Round numbers start at 0.

  1. Round 0scene_read

    Measure the coin and slot before choosing the grasp pose.

    Target: Coin, holder and bank slot

    Previous step: none

    Next: Read the simulator scene geometry with both arms stationary.

  2. Round 1move_pose

    A vertical approach with the jaw axis along the coin’s face normal gives access to both faces above the holder.

    Target: Space above the coin

    Previous step: met — round-0 scene_read, obs-5b901f73a16e4255

    Next: Move the open left gripper to (−0.1276,−0.1749,0.8550) m, 60 mm above the coin’s upper edge, with the jaws along (−0.338,0.941,0).

  3. Round 2run_programscene_readmove_posewait_ticksscene_readgrasp_and_verifyscene_read

    The coin is between the open jaws in the wrist view. A straight descent can place the fingertips on either side of its exposed upper half.

    Target: Exposed upper half of the coin

    Previous step: met — action-49896a79a9ee460d80c182b0d58d5ad5, obs-d56f73ed318c4c76

    Next: Read the current coin and stand poses, descend to about (−0.128,−0.175,0.786) m, then close and lift 60 mm if the settled fingertips overlap the coin above the holder.

    Moved: coin0

  4. Round 3run_programscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readmove_posewait_ticksscene_read

    Pickup is verified. The coin needs to rise above the bank before moving sideways toward the slot.

    Target: Space above the bank slot

    Previous step: met — program 3fa1e4d23944, obs-f046413f378b4d9c

    Next: Raise the left fingertips to about z=0.940 m, carry the coin above the slot near (−0.326,−0.188) m, then turn it edge-on to the opening using fresh scene measurements.

  5. Round 4run_programscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_read

    The wrist image places the dark opening about 4.6–5.1 mm wide near its middle. The coin is aligned lengthwise, but its 1.5 mm lateral offset uses nearly all the available clearance.

    Target: Coin bank opening

    Previous step: met — program c220b94b9030, obs-bf8f092a1de34b61

    Next: Center the coin over the measured slot, lower its bottom edge about 10 mm through the opening, then release if alignment and insertion depth are confirmed. Read the coin pose after it settles.

  6. Round 5run_programcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_readcarry_towait_ticksscene_read

    The coin slipped upward between the fingers during descent, and further downward travel brought the fingers against the bank. I’ll lift clear, recenter the coin and release it edge-first close to the opening.

    Target: Coin at the bank slot

    Previous step: not_met — program e81af523a37b, obs-728aa2eba5e6406c

    Next: Lift the closed fingers 28 mm. Use fresh coin and slot poses to center the lower edge about 2 mm above the opening, allow the arm to settle, then open and verify the drop.

  7. Round 6run_programscene_readmove_posewait_ticksscene_readset_gripperwait_ticksscene_readmove_towait_ticksscene_read

    The coin is centered to within 0.04 mm across the opening. Its 4.8-degree lean shifts the lower edge about 1.2 mm toward one lip. Correcting that lean will give the coin more clearance.

    Target: Coin lower edge over the slot

    Previous step: not_met — program 163267cb415c, obs-1929bb7f7a964ae7

    Next: Rotate the hand about the slot’s long axis to bring the coin upright, recenter its lower edge using the measured pose, then open the jaws and withdraw vertically.

    Moved: coin0

  8. Round 7finish_episode

    The coin was picked up from its holder and inserted through the bank slot.

    Target: Coin inside the bank

    Previous step: met — program 385c144f54cd, obs-40d53f1a3aec429b

    Next: Finish the episode.

The Other Runs on This Task