Desk · layout 45 · gpt-6.2-astra · open coordinates

B601 · Zoetic harness 0.4.51 · 22 rounds · 30 requests · 3.68M input tokens · 12 min model time · 47 min wall clock

MetRoboDojo graded score 100Not within RoboDojo’s step limitModel declared the task finishedGPU physics

“Place the mouse on the mouse pad, push the keyboard into the frame, put the figurine on the stand, place the alarm clock on the drawer, then open the drawer and put all remaining miscellaneous items inside.”

The task. Five steps on a desk: mouse on the pad, keyboard into its frame, figurine on its stand, alarm clock on the drawer, then open the drawer and put the remaining small items in it.

What the model had. Everything in sensor-only mode, plus a tool, scene_read, that asks the simulator for each object’s position, orientation and size (simulation only). Its opening note asked it to consider spatial information first and to report which values it used. It called scene_read 90 times, 89 of them inside its own programs.

Host’s offline check. All original conditions met. All condition groups were first met at control step 2,034; RoboDojo’s limit for this task is 1,000. The model never saw this check.

The last two rounds. The model lifted the figurine 25 mm and put it on the stand. A last pull on the drawer did not measurably move the handle; it reported the four placements done and no loose items left.

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of simulated motion. “Moved” means an object shifted at least 5 mm. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them: its judgment, its target for the round, its check of the previous step, and its next step. Names such as place_and_release, scene_read and run_program are harness tools it could call; tools indented under run_program ran inside one of its programs. Round numbers start at 0.

  1. Round 0scene_readalign_plan

    The mouse and pad are both on the right side of the desk. The right arm is the nearer arm for the first placement.

    Target: Mouse and mouse pad

    Previous step: none

    Next: Read the scene and obtain a right-arm approach candidate above the mouse at head pixel (436,234).

  2. Round 1run_programscene_readmove_posescene_readmove_posescene_readgrasp_and_verifyscene_readplace_and_releasescene_read

    The right gripper can approach from above with its jaws across the mouse. The pad has room for the entire mouse footprint.

    Target: Mouse

    Previous step: met, round 0 scene_read and align_plan, obs-27f262cda3c64ab3

    Next: Approach above (0.253,-0.084), descend to 8 mm above the table, lift, and place at the pad center if the mouse rises. Refresh scene coordinates between motions.

    Moved: mouse

  3. Round 2run_programscene_readmove_poseset_gripperscene_readmove_posescene_readmove_posescene_readmove_posescene_readscene_read

    The keyboard is wider and deeper than the marked frame. I’ll center it over the frame. Moving it right first gives the figurine clearance and reduces overlap with the clock during the forward push.

    Target: Keyboard and frame

    Previous step: met, 98d5cbd1bcd3 and obs-b4b3a446e3684111

    Next: Use the left gripper to push the keyboard’s left edge toward +x, then use the right gripper at the near edge to push toward +y. Recompute each contact from live scene poses.

    Moved: keyboard

  4. Round 3run_programrecover_posescene_readmove_posescene_readmove_posescene_readcarry_toscene_readcarry_toscene_readcarry_toscene_readmove_posescene_read

    The first push shifted and rotated the keyboard. A slow push against the near edge with both open fingertips can correct the angle while advancing it.

    Target: Keyboard near edge

    Previous step: partly, e18682a5259c and obs-444773b4a6aa45ee

    Next: Retract the left arm. Approach the near edge with the right fingertips level and spaced along x, then push toward the frame in measured increments.

  5. Round 4run_programscene_readmove_posescene_readmove_posescene_readcarry_toscene_readcarry_toscene_readcarry_toscene_readmove_posescene_readgeometry_query

    The forward push put the keyboard over the frame. A leftward correction from its right edge will bring the centers together.

    Target: Keyboard right edge

    Previous step: met, 75f67694e6b0 and obs-c1e76ca14ca643f3

    Next: Place the open right fingertips outside the keyboard’s right edge, between it and the pad. Push left slowly with the fingers spaced front to back, then measure the figurine’s head and torso with RGB-D.

  6. Round 5run_programscene_readmove_posescene_readmove_pose · not reachedscene_read

    The keyboard’s lateral alignment is within 4 mm. A short push toward the robot will correct its remaining 47 mm fore-aft offset.

    Target: Keyboard far edge

    Previous step: partly, 8484b44130b0 and obs-343300bf87b94d17

    Next: Reach behind the keyboard from the right with the wrist tilted toward the robot. Push the far edge toward y=0 in short steps and withdraw vertically.

  7. Round 6run_programscene_readmove_pose · not reachedscene_readmove_posescene_read

    The tilted approach stopped above the keyboard. A steeper wrist angle changes the folded joint configuration and keeps the fingertips in the narrow gap.

    Target: Keyboard far edge

    Previous step: not_met, 9a6db74c8f3d and obs-0603cf3692e14a2a

    Next: Try a near-vertical descent at (0.131,0.147,0.774) m, then a gentle push toward y=0.084 and a retreat if reached.

  8. Round 7run_programset_gripperscene_readmove_posescene_readmove_posescene_readgrasp_and_verifyscene_readplace_and_releasescene_read

    The keyboard center is inside the marked frame, though it remains near the far edge. The left arm can now transfer the figurine to the small square stand.

    Target: Figurine and square stand

    Previous step: not_met, a93cd154d80f and obs-6594f73bdd554309

    Next: Open the left gripper, approach the figurine from above, and grasp around the torso near (-0.271,-0.111,0.875). Check the base rises, then place it using the measured offset between the grasp and base.

    Moved: garage

  9. Round 8run_programscene_readcarry_toscene_readcarry_toscene_readcarry_toscene_read

    The figurine is still held. Its base tilted toward the robot during transport, so the original grasp-to-base offset no longer predicts the release point.

    Target: Held figurine

    Previous step: partly, ec6992e70e81 and obs-bf9f2b4368a54745

    Next: Lower the figurine near the table before advancing farther. Use short translations based on the live base marker and release only when the base is over the stand and close to its surface.

    Moved: garage

  10. Round 9run_programscene_readmove_posescene_readcarry_toscene_readcarry_toscene_readcarry_toscene_read

    A rotation of about +30° around world x should bring the tilted base under the torso and extend the gripper’s approach toward the stand.

    Target: Figurine base over stand

    Previous step: not_met, a405944648ea and obs-387d2c4745034942

    Next: Tilt the wrist while keeping the figurine elevated. Recompute the offset from fingertip to base, carry toward the stand in short steps, and lower at its center.

    Moved: garage

  11. Round 10run_programscene_readplace_and_releasescene_readmove_poseset_gripperscene_readmove_posescene_readcarry_toscene_readcarry_toscene_readcarry_tomove_posescene_read

    The figurine is nearly upright and close to the table. Setting it down here allows a low push on its base, clear of the drawer cabinet at torso height.

    Target: Figurine base

    Previous step: not_met, d0b50a00b833 and obs-a4b419209b0840b9

    Next: Lower the figurine onto the table and withdraw. Push its round base diagonally toward the stand using the measured base center, then check its final pose.

    Moved: alarm, garage, keyboard

  12. Round 11run_programrecover_poseset_gripperscene_readmove_posescene_readmove_posescene_readgrasp_and_verifyscene_readcarry_toscene_readplace_and_releasescene_read

    Moving the clock clears the space beside the stand. The drawer has a recessed top surface suitable for the clock.

    Target: Alarm clock and drawer top

    Previous step: partly, d9cf95e6b17c and obs-c665f7f6d4ed4a6d

    Next: Grasp the clock along its 80 mm axis to keep the open fingers clear of the figurine. Lift it clear of the cabinet rim, carry it over the recessed top near (-0.40,0.11), then lower and verify.

    Moved: alarm, garage

  13. Round 12run_programscene_readcarry_toscene_readscene_read

    The clock cleared the rim and is still upright in the left gripper. A shorter route to the near-right portion of the top gives the whole clock enough support.

    Target: Held clock above drawer rim

    Previous step: partly, 2417fd31899f and obs-de5b58c00ccf41cd

    Next: Move left first to x≈−0.335, then toward y≈0.10 above the recessed surface. Lower and release once the full clock footprint is inside the rim.

    Moved: alarm

  14. Round 13run_programscene_readmove_posescene_readcarry_toscene_readscene_read

    The shorter carry identified a robot self-collision limit. Turning the wrist about its downward approach axis can change the arm configuration while keeping the clock upright.

    Target: Clock over drawer top

    Previous step: not_met, 1b48b4295f02 and obs-d0d02ff2e6074d99

    Next: Turn the wrist toward a transverse jaw orientation, carry to approximately (-0.34,0.11,1.07), and place after checking the clock base is inside the rim.

    Moved: alarm

  15. Round 14run_programscene_readmove_posescene_readplace_and_releasescene_read

    The rotated clock now spans mostly along x, reducing the depth it needs on the drawer top. A short diagonal descent can increase its front-edge clearance.

    Target: Clock release point

    Previous step: not_met, 0ff2530ff7ec and obs-7e5449d4a4314d5f

    Next: Move the fingertips about 18 mm left, 30 mm farther onto the top, and 42 mm down with a more forward approach. Use the measured base offset for the final descent.

    Moved: alarm

  16. Round 15run_programgeometry_querymove_posegeometry_querymove_pose · not reachedscene_read

    The handle protrudes about 29 mm from the drawer face. It can be pinched across its roughly 21 mm height and pulled toward the robot.

    Target: Drawer handle

    Previous step: met, 78b031766896 and obs-6804d6afbf0f47bd

    Next: Approach the handle from the front with the left jaw axis vertical, close near (-0.400,0.039,0.919), and make a 45 mm test pull. Measure the handle with RGB-D before extending farther.

  17. Round 16run_programgeometry_querymove_poseset_gripper · not reachedcarry_togeometry_query

    The horizontal approach reached a joint limit before contact. A downward-sloping approach can reach the same handle with less elbow extension.

    Target: Drawer handle

    Previous step: not_met, 50e6993c31cf and obs-fb33a329656b4daa

    Next: Approach the protruding handle near (-0.400,0.031,0.916) m with the fingertips sloping downward. Pinch across its height and pull toward negative y if closure indicates contact.

  18. Round 17run_programset_gripperrecover_posescene_readmove_posescene_readmove_posescene_readmove_toscene_readmove_to · not reachedscene_readmove_to · not reachedmove_posescene_read

    The handle stayed at its closed position during a verified pull. The simulator lists the drawer as geometry without a slide joint. I’ll correct the keyboard’s fore-aft position using contact from above.

    Target: Keyboard and frame

    Previous step: not_met, a8a2f1a94460 and obs-60e6f7f7e04c4953

    Next: Withdraw the left arm. Put the right fingertips on the keyboard near its center and slide toward the robot in short steps, reading the keyboard and frame after each step.

    Moved: keyboard

  19. Round 18run_programscene_readmove_posescene_readmove_pose · not reachedscene_readmove_to · not reachedscene_readmove_to · not reachedscene_readmove_to · not reachedmove_posescene_read

    The keyboard center is back inside the frame, and its long edge is parallel to the outline. One short stroke from farther back on the keys can bring the full frame underneath it.

    Target: Keyboard center

    Previous step: met, 58b89738815e and obs-fd87db59e90044fb

    Next: Contact the middle of the keyboard from above and move the gripper toward the frame center using the remaining measured offset. Retreat and check all object poses.

    Moved: keyboard

  20. Round 19run_programscene_readmove_posescene_readmove_posescene_readgrasp_and_verifyscene_readwait_ticksscene_readcarry_toscene_readplace_and_releasescene_read

    The figurine stands upright with its base overlapping the stand. A 26 mm shift to the right will put its center over the stand center.

    Target: Figurine on square stand

    Previous step: met, 6ef9acdd30bb and obs-c85ed38abf844015

    Next: Use the left gripper to grasp the upper body with the jaw line front to back, lift about 25 mm and move the measured base to (-0.150,0.100).

    Moved: garage

  21. Round 20run_programrecover_posemove_posegeometry_querymove_posegeometry_querymove_to · not reachedmove_poserecover_posegeometry_queryscene_read

    All four loose objects are now on their requested supports. A second pull with a deeper grip can distinguish a slipping grasp from a drawer that has no simulated travel.

    Target: Drawer handle and front panel

    Previous step: met, b52c3ffc6a0c and obs-67f99b0393d84873

    Next: Withdraw from the figurine, grasp closer to the root of the drawer handle, and pull in short increments. Compare the exposed handle end and panel with their original depth after withdrawing.

  22. Round 21finish_episode

    All four placements are complete. The drawer remains closed. The scene contains no additional loose items to put inside.

    Target: Final desk arrangement

    Previous step: met, 089bc427575d and obs-8204dd1eafd14813 confirm the handle and panel remain at their closed coordinates

    Next: Finish the episode with the drawer-opening step recorded as incomplete.

The Other Runs on This Task