Desk · layout 45 · gpt-6.2-astra · sensor-only

B601 · Zoetic harness 0.4.51 · 39 rounds · 108 requests · 13M+ input tokens · 50 min model time · 156 min wall clock

Not metRoboDojo graded score 75Not within RoboDojo’s step limitModel declared the task finishedCPU physics

“Place the mouse on the mouse pad, push the keyboard into the frame, put the figurine on the stand, place the alarm clock on the drawer, then open the drawer and put all remaining miscellaneous items inside.”

The task. Five steps on a desk: mouse on the pad, keyboard into its frame, figurine on its stand, alarm clock on the drawer, then open the drawer and put the remaining small items in it.

What the model had. Color and depth images from the three cameras, the camera calibration and the robot’s own readings, as on a real robot. Its opening note only pointed to where spatial information can be found.

Host’s offline check. The alarm clock was not upright enough. The task run ended at control step 4,118; RoboDojo’s limit for this task is 1,000. The model never saw this check.

The last two rounds. The model pushed the keyboard edge, then tried to pull the drawer with both hands. It reported four placements done, the drawer still closed and nothing else put away.

Head camera
Left wrist
Right wrist
  • Moved an object
  • Moved the arm only
  • Failed or stopped
  • Width = seconds of simulated motion. “Moved” means an object shifted at least 5 mm. Select a segment to jump to it.

Model Report, Round by Round

As the model wrote them: its judgment, its target for the round, its check of the previous step, and its next step. Names such as place_and_release, scene_read and run_program are harness tools it could call; tools indented under run_program ran inside one of its programs. Round numbers start at 0.

  1. Round 0run_program · errormove_pose

    The mouse is within reach of the right arm. The center of the pad provides clearance around its footprint.

    Target: Mouse and mouse pad

    Previous step: none

    Next: Approach the mouse from above, grasp across its width, and place it at the pad center if the lift indicates a hold.

  2. Round 1run_programmove_tograsp_and_verifyplace_and_releaserecover_pose

    The approach succeeded. I used incorrect syntax to read its status, which stopped the program before descent. The corrected program resumes from the measured pose.

    Target: Mouse

    Previous step: not_met — obs-a382c8703b3c4766 shows the mouse still on the desk.

    Next: Lower the right gripper around the mouse, lift, and place on the pad if the fingers indicate a hold.

    Moved: mouse

  3. Round 2run_programmove_poseset_grippercarry_tocarry_tomove_poserecover_pose

    The keyboard needs to move right and then away from the robot. A sideways push first gives it clearance from the clock.

    Target: Keyboard left edge

    Previous step: met — program a2ee32f1a60d measured opening and retreat, and obs-9e9bcadb3db043cd shows the mouse inside the pad edges.

    Next: Push the middle of the keyboard’s left edge about 14 cm to the right, lift the gripper, and inspect alignment before the forward push.

    Moved: keyboard

  4. Round 3run_programmove_posecarry_tomove_poserecover_pose

    The keyboard is now laterally aligned for a forward push. Its left end is slightly closer to the robot, so the left finger should contact first and help straighten it.

    Target: Keyboard near edge

    Previous step: met — obs-c5e5d43392354c32 shows the keyboard shifted right and still flat, with a small rotation.

    Next: Use the open right gripper to push the keyboard’s near edge toward the monitor, then withdraw for a clear view.

  5. Round 4run_programset_grippermove_posecarry_tocarry_tomove_poserecover_pose

    The left arm can approach the same edge from farther across the desk, which changes the joint configuration that blocked the right arm.

    Target: Keyboard near edge

    Previous step: not_met — obs-4297ba7072864183 shows the keyboard still in front of the frame.

    Next: Open the left gripper and use its two fingers to push the keyboard forward from the near edge.

    Moved: alarm, keyboard

  6. Round 5run_programmove_posecarry_to

    The small silver square behind the figurine is the most plausible stand. I’ll center the figurine’s round base on it.

    Target: Figurine and silver stand

    Previous step: met — obs-694c6bbe1709446f shows the keyboard center over the frame and both arms clear. The keyboard remains angled.

    Next: Grasp the figurine around its torso with the left arm, lift it upright, and lower its base onto the silver square.

    Moved: garage

  7. Round 6run_programgrasp_and_verifyplace_and_release

    The wrist view shows the torso between the jaws at the measured stop height. The gripper can close there without descending farther.

    Target: Figurine torso

    Previous step: not_met — obs-a68c3ffb7bd54a1f shows the figurine still at its starting location.

    Next: Close at the current pose, test the lift, and place the base on the stand if the lift and finger measurements indicate a hold.

    Moved: garage

  8. Round 7run_programcarry_tocarry_to

    The suspended base is offset toward the robot from the fingers. A lateral move away from the drawer followed by a forward move will bring the base over the stand.

    Target: Suspended figurine

    Previous step: partly — program f02e6f46e5f1 and obs-08ff5aed4b864efd confirm the lift. Placement is pending.

    Next: Carry the figurine sideways first, then forward. Lower and release it over the stand if both moves succeed.

    Moved: garage

  9. Round 8run_programmove_poseplace_and_release

    Tilting the gripper toward the stand can bring the hanging base forward and closer to level while allowing a shorter forward reach.

    Target: Figurine base and stand

    Previous step: not_met — obs-14cde41aee824f93 and program 441de4c541ab show the figurine still held.

    Next: Change the left wrist pitch while holding the figurine, then approach the stand at a lower height and release if alignment succeeds.

    Moved: garage

  10. Round 9run_programset_grippermove_poseset_grippermove_posecarry_tocarry_tomove_poserecover_pose

    Depth puts the round base center near [-0.135, 0.05] m. Its back edge overlaps the stand, so a short push at base level should center it more closely.

    Target: Figurine base

    Previous step: partly — obs-93f879f219084ba1 shows an upright figurine and overlap with the stand. The gripper has yet to open and withdraw.

    Next: Open and withdraw the left gripper, then gently push the near edge of the round base toward the center of the stand.

    Moved: alarm, garage

  11. Round 10run_programset_grippermove_pose · not reached

    The clock’s exposed casing can be grasped across its short dimension. The route to the drawer should pass in front of the figurine, then rise above the drawer rim.

    Target: Alarm clock and drawer top

    Previous step: partly — obs-bf5f208f30ba4ac0 confirms upright support and overlap. The clock obscures part of the base, limiting the center estimate.

    Next: Grasp the clock with the left arm, carry it clear of the figurine, and lower it onto the drawer top.

  12. Round 11run_programmove_pose · not reached

    The first approach stopped high above the desk. A staged approach with the jaw line closer to its initial direction should avoid the joint configuration that blocked it.

    Target: Alarm clock

    Previous step: not_met — obs-ca8a767601fc4bed shows the clock still on the desk.

    Next: Approach from in front of the clock with the left wrist pitched forward, then grasp, lift, and place it on the drawer top.

  13. Round 12run_programrecover_posemove_posemove_posemove_posegrasp_and_verify

    The left arm has already reached a low pose in front of the drawer from home. Reusing that path will let it approach the clock from desk height.

    Target: Alarm clock casing

    Previous step: not_met — obs-5d2c0a5465ef4c68 shows the clock still on the desk.

    Next: Return home, move to the previously reached waypoint, then approach the clock from the front and test the grasp.

    Moved: alarm

  14. Round 13run_programmove_pose · not reached

    The clock now rests on an edge. Two measured casing faces give a new approach direction and an opposing jaw direction for the tilted grasp.

    Target: Tilted alarm clock

    Previous step: not_met — program 64cb49f8d1dd and obs-2c1051416edb4287 show the clock on the desk after the lift.

    Next: Align the jaws to the measured faces, grasp near the casing center, and carry the clock to the drawer if the lift holds.

  15. Round 14run_programcarry_tograsp_and_verifycarry_tocarry_tocarry_toplace_and_releaserecover_pose

    The gripper stopped within 8 mm and 8 degrees of the approach pose. Its measured orientation is close enough for a straight approach to the casing.

    Target: Alarm clock casing

    Previous step: not_met — obs-436e89c3e537485b shows the clock still on the desk.

    Next: Keep the current wrist angle, translate to the clock, close, and lift. Continue toward the drawer only if the clock stays held.

    Moved: alarm

  16. Round 15run_programmove_pose · not reached

    The handle projects about 29 mm from the drawer face. The left gripper can pinch its top and bottom surfaces and pull straight toward the robot.

    Target: Drawer handle

    Previous step: met — program 8738a4bbec64 and obs-9434eb5039b24576 confirm the lift and placement.

    Next: Approach the handle from the front, close vertically around it, pull outward, and release once the drawer has traveled far enough to expose its interior.

  17. Round 16run_programrecover_posemove_posemove_pose · not reached

    The direct route from home stopped before reaching the drawer. The low waypoint used for the clock provides another route to handle height.

    Target: Drawer handle

    Previous step: not_met — obs-1ccbc459f35341ee shows no drawer travel.

    Next: Approach through the low waypoint, rotate the jaws toward vertical in front of the handle, then grip and pull.

  18. Round 17run_programcarry_tomove_pose · not reached

    The arm reached desk height. Translating closer with its current pitch before turning toward the handle avoids the blocked combination of translation and rotation.

    Target: Right half of drawer handle

    Previous step: not_met — obs-c61f95c9ca4342d3 shows the handle has not moved.

    Next: Move in front of the handle, turn the gripper toward its right end, and pinch the handle from above and below before pulling.

  19. Round 18run_programset_grippermove_posecarry_tocarry_tomove_poserecover_pose

    The current steep approach can reach the broad top of the handle. Pressing there and drawing outward provides a pull without another large wrist turn.

    Target: Top surface of drawer handle

    Previous step: not_met — obs-11e86a5d8716493f shows the closed drawer.

    Next: Close the fingers in free space, lower them onto the handle top, and pull outward while maintaining contact height.

  20. Round 19run_programset_grippermove_posemove_pose · not reached

    The fingers slid across the handle without opening the drawer. A pinch from the left end can engage both its upper and lower surfaces while keeping the wrist in front of the cabinet.

    Target: Left end of drawer handle

    Previous step: not_met — obs-16393b9d214f4ad3 shows no exposed drawer interior.

    Next: Approach the left end of the handle from the side, pinch across its thickness, and pull toward the robot.

  21. Round 20run_programcarry_to

    At the measured angle the open fingers differ in height by about 48 mm. This is enough to put one above the handle and the other below its left corner.

    Target: Left corner of drawer handle

    Previous step: not_met — obs-192ca208f2294133 shows the drawer still closed and the gripper open.

    Next: Translate at the current angle to straddle the handle corner, close, and pull outward at constant height.

  22. Round 21run_programmove_poseset_gripper · not reachedcarry_toset_grippermove_poserecover_pose

    The fingers are aligned with the handle corner but stopped 19 mm short in depth. A small change in pitch should permit the remaining insertion.

    Target: Drawer handle corner

    Previous step: not_met — program b19aeadec1fb and obs-8b874fcaf2c24e43 show no pull yet.

    Next: Advance the open gripper with a slightly more forward pitch, close on the corner, and pull outward.

  23. Round 22run_programmove_posemove_posecarry_toset_gripper · not reachedcarry_to

    The corner pinch slipped. The arm model gives a route to the handle center with nearly vertical jaws and clearance between the two links that previously blocked the turn.

    Target: Drawer handle center

    Previous step: not_met — obs-53b31cd629244818 shows no persistent opening.

    Next: Follow the calculated approach, pinch the handle center, and pull straight outward. Hold the final pose for inspection.

  24. Round 23run_programset_grippercarry_tomove_posecarry_toset_gripper · not reachedcarry_toset_gripper · not reachedcarry_to

    The measured handle depth is identical to its starting depth. A deeper, nearly horizontal insertion will place both fingers over more of the handle before a short diagnostic pull.

    Target: Center of drawer handle

    Previous step: not_met — obs-446cd72fb1384ce8 shows the drawer closed while the arm still holds its final pull pose.

    Next: Seat the fingers near the back of the handle, pinch vertically, and inspect the drawer after a short pull.

  25. Round 24run_programcarry_toset_gripperrecover_posemove_poseset_grippercarry_tocarry_tomove_poserecover_pose

    The short pull slipped. The keyboard can now be centered more closely while the drawer handle is clear.

    Target: Keyboard and frame

    Previous step: not_met — 9308436fd667, obs-e96adddd4a16469c

    Next: Withdraw the left hand, then use the closed right gripper to push the keyboard leftward just behind its center.

  26. Round 25run_programset_grippermove_pose

    The keyboard is closer to the frame center and straighter. The next step is to inspect the drawer from below before attempting another pull.

    Target: Lower drawer edge

    Previous step: met — obs-434692e807384c66 and program 175b104b9ac0

    Next: Close the empty left gripper and position its camera below and in front of the drawer.

  27. Round 26run_programcarry_tocarry_to

    The handle has a flat underside accessible from the front. The panel below it extends back into the cabinet, with no visible gap for a hook. The left hand can test whether upward pressure on the handle gives enough grip to pull the drawer.

    Target: Drawer handle underside

    Previous step: met — obs-60083e7411984342, action-2c66d25f2c04435397b2578bebbd7eae

    Next: Seat the closed left fingertips beneath the handle and pull toward the robot in short steps while maintaining upward pressure.

  28. Round 27run_programcarry_tocarry_tocarry_tocarry_to

    The fingers reached beneath the handle. The upward motion stalled and the program stopped before the outward pull.

    Target: Drawer handle underside

    Previous step: not_met — obs-9ded157c815d44e1 and program 25787fd5e194. The drawer remained closed.

    Next: Draw the closed fingers outward from their measured position while raising them against the handle underside.

  29. Round 28run_programrecover_posemove_posemove_pose · not reached

    The underside pull did not open the drawer. A rear view can show whether there is an exposed drawer panel to push toward the robot.

    Target: Rear of drawer cabinet

    Previous step: not_met — obs-3b7d608c152d44e6 and program 37407953bf6d

    Next: Move the left wrist camera above the rear right corner of the cabinet and inspect the back.

  30. Round 29run_programmove_poserecover_poseset_grippermove_posemove_posecarry_to

    The cabinet back blocks access to the drawer from behind. At the front, the fingers can lie along the handle’s long axis, giving them more contact with its upper and lower faces.

    Target: Front drawer handle

    Previous step: met — obs-8b8d4f9151c640ab and action-80cbad01f7994e5cb29bb32cc24b1072

    Next: Withdraw above the cabinet, approach the front handle from its right end, close the left jaws lengthwise, and pull in short increments while checking the finger gap.

  31. Round 30run_programset_gripper · not reachedcarry_toset_gripper · not reachedcarry_toset_gripper · not reachedcarry_toset_gripper · not reachedcarry_to

    The shallow overlap is enough to test a pinch. Finger separation during a small inward adjustment will indicate whether the grip is worth pulling.

    Target: Drawer handle

    Previous step: not_met — obs-92212a0261b14286 and program 8c1c90e8ffe4

    Next: Close the left fingers at the measured position, seat them slightly farther onto the handle, then pull outward while the gap indicates contact.

  32. Round 31run_programcarry_toset_gripperrecover_posemove_pose

    The lengthwise grip slipped. The next unresolved item is the tan strip at the mouse pad’s near edge. Its center sits lower than the dark ridges on either side.

    Target: Tan strip at mouse pad edge

    Previous step: not_met — obs-907d4c8a62334ecc and program c8209d2a3e96

    Next: Withdraw the left hand from the drawer and position the right wrist camera above the pad’s near edge.

  33. Round 32run_programrecover_poseset_grippermove_posemove_posecarry_toset_gripper · not reachedset_grippermove_posemove_posecarry_toset_gripper · not reachedmove_pose

    The tan strip appears to be a recess in the pad. The drawer remains closed after the single-arm pulls. Both arms have candidate approach paths to opposite ends of the handle.

    Target: Both ends of the drawer handle

    Previous step: met — obs-81b0fd69de504282 and action-16424227943f4f8a9536da33b5fdcd57

    Next: Grip the right and left ends of the handle. Pull both hands toward the robot together if both finger gaps indicate contact.

  34. Round 33run_programset_grippermove_posemove_pose · planner failedmove_pose · planner failedmove_pose · not reached

    Both pinches slipped. The two end faces offer a different grip: the arms can squeeze the handle along its length while pulling outward.

    Target: Drawer handle end faces

    Previous step: partly — obs-bed26cc44b1542f8 and action-aac993d12a0945988f26df62f9141110. Both grippers engaged, but the drawer did not move.

    Next: Position the closed fingertips just outside the handle ends, press inward with both arms, then pull forward while maintaining the squeeze.

  35. Round 34run_programcarry_tocarry_tomove_posemove_posemove_posemove_posemove_pose

    The planner stopped the simultaneous squeeze before either end face was firmly engaged. Shorter, separate approaches can test contact from the current positions.

    Target: Drawer handle end faces

    Previous step: not_met — obs-837e5f369fb74264 and action-bc46fdd656ef43c78beff57afafad3ac

    Next: Seat each closed hand against its handle end separately, then pull both hands forward in short steps while maintaining inward pressure.

  36. Round 35run_programrecover_posecarry_tocarry_towait_ticksmark_pointcarry_toset_gripperrecover_posewait_ticks

    The end-face squeeze did not open the drawer. An inward press followed by release can test for a push latch, whose presence is unverified.

    Target: Drawer front and handle

    Previous step: not_met — obs-53b60795a8c54b5a and action-1e7d60f4246541aba39ca8d29c133e71

    Next: Retract the right arm, press inward on the handle with the closed left fingertips, then withdraw and inspect the drawer.

  37. Round 36run_programmove_poseset_grippercarry_tocarry_tomove_poserecover_pose

    The press produced no measurable drawer movement. The keyboard still sits about 30 mm left of the frame center and is angled about 8° clockwise. A short push at its near-left edge can improve both.

    Target: Keyboard near-left edge

    Previous step: not_met — obs-ebe75cd163ca4a04 and obs-ce02ae5cd6ce4bf7 show no latch release or outward travel.

    Next: Use the left gripper to nudge the keyboard rightward near its front-left corner, then withdraw and measure its position.

    Moved: keyboard

  38. Round 37run_programset_grippermove_posemove_posecarry_toset_gripper · not reachedset_grippermove_posemove_posecarry_toset_gripper · not reachedmove_poseset_gripper · not reachedmove_posemove_poseset_grippermove_poserecover_posemove_pose · not reachedrecover_pose

    The keyboard adjustment met its target. The remaining drawer test is to lift the gripped handle slightly before pulling, in case vertical loading affects its travel.

    Target: Drawer handle

    Previous step: met — obs-ca80ba47b96945bf and program fed351800e81

    Next: Grip both handle ends, raise the hands slightly, then pull outward while retaining the raised grip. Withdraw both arms for inspection.

  39. Round 38finish_episode

    Four placements are complete. The drawer stayed closed, and no items were stowed.

    Target: Drawer and remaining desk items

    Previous step: not_met — obs-0a56195e1f294469 and program 47f205974109 show no drawer travel or exposed interior.

    Next: End the episode with partial completion. Both arms are home with open grippers.

The Other Runs on This Task